Page 3 of 3 Compact Fluorescent
200
400
30°
60°
90°
100
300
8091CL-D6AO1
Calculite 6" Vetro Downlight, Cat.# 8091CL/D6A01 Opal Lens
32W Sylvania Dulux T/E Triple Tube. Lumen Rating = 2400 LMS.
Universal Ballast #C2642UNVBES(#1)
Candlepower Summary
Angle Along 22.5 45 67.5 Across LMS
0 460 460 460 460 460
5 447 447 448 449 448 43
10 425 425 426 428 428
15 393 394 396 398 398 112
20 356 357 360 363 364
25 316 317 320 325 327 148
30 274 275 278 284 288
35 231 232 237 245 251 150
40 188 189 194 204 207
45 148 149 152 158 160 119
50 111 111 111 112 113
55 50 50 51 53 54 58
60 42 42 43 44 44
65 36 37 37 37 38 37
70 32 32 32 33 33
75 28 28 28 28 28 30
80 25 25 25 25 25
85 23 23 23 23 23 25
90 20 20 20 21 20
Zonal Lumens and Percentages
Zone Lumens % Lamp %Luminaire
0-30 302 12.61 41.97
0-40 452 18.84 62.73
0-60 629 26.21 87.25
0-90 721 30.04 100.00
40-90 268 11.20 37.27
60-90 91 3.83 12.75
90-180 0 .00 .00
0-180 721 30.04 100.00
** Efciency = 30.0% **
Certified test report no. 3517FR
Computed by LSI program **TEST-LITE**
SC = 1.0
Prepared For:
Lightolier
Fall River, MA
Coefficients of Utilization
Ceiling 80% 70% 50% 30% 10%
Wall 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
RCR Zonal Cavity Method - Effective Floor Reflectance = 20%
Room Cavity Ratio
0 .36 .36 .36 .36 .35 .35 .35 .35 .33 .33 .33 .32 .32 .32 .31 .31 .31 .30
1 .33 .32 .31 .30 .33 .32 .31 .30 .30 .29 .29 .29 .28 .28 .28 .28 .27 .26
2 .31 .29 .28 .26 .30 .29 .27 .26 .28 .26 .25 .27 .26 .25 .26 .25 .24 .24
3 .29 .27 .25 .23 .28 .26 .24 .23 .25 .24 .23 .25 .23 .22 .24 .23 .22 .21
4 .27 .25 .22 .21 .27 .24 .22 .21 .23 .22 .20 .23 .21 .20 .22 .21 .20 .19
5 .26 .23 .20 .19 .25 .22 .20 .19 .22 .20 .18 .21 .20 .18 .21 .19 .18 .18
6 .24 .21 .19 .17 .23 .20 .18 .17 .20 .18 .17 .20 .18 .17 .19 .18 .17 .16
7 .22 .19 .17 .15 .22 .19 .17 .15 .18 .16 .15 .18 .16 .15 .18 .16 .15 .14
8 .21 .18 .15 .14 .21 .17 .15 .14 .17 .15 .14 .17 .15 .14 .16 .15 .14 .13
9 .20 .16 .14 .13 .19 .16 .14 .13 .16 .14 .13 .15 .14 .12 .15 .14 .12 .12
10 .18 .15 .13 .11 .18 .15 .13 .11 .15 .13 .11 .14 .13 .11 .14 .12 .11 .11
Determined In Accordance With Current IES Published Procedures
Luminaire Input Watts = 38.0
Tested According to IES Procedures. Test Distance Exceeds Five
Times the Greatest Luminous Opening of Luminaire.
150
300
30°
60°
90°
75
225
8011CL-D4AO1
Calculite 4” Vetro Downlight, Cat.# 8011Cl D4A01
18W G.E. Biax T/E triple Tube. Lumen Rating = 1200 LMS.
Universal Ballast #C218UNVBES
Candlepower summary
Angle Mean CP Lumens
0 244
5 239 23
10 254
15 263 73
20 255
25 233 107
30 204
35 174 107
40 131
45 56 51
50 21
55 17 16
60 15
65 13 13
70 12
75 10 11
80 9
85 9 10
90 8
SC(Along) = 1.3, SC(Across) = 1.5
Certied test report no. 3557FR
Computed by LSI program **TEST-LITE**
SC = 1.2
Prepared For:
Lightolier
Fall River, MA
Zonal Lumens and Percentages
Zone Lumens % Lamp %Luminaire
0-30 203 16.97 49.50
0-40 311 25.92 75.59
0-60 377 31.49 91.85
0-90 411 34.29 100.00
40-90 100 8.37 24.41
60-90 33 2.79 8.15
90-180 0 .00 .00
0-180 411 34.29 100.00
** Efciency = 34.3% **
Coefficients of Utilization
Ceiling 80% 70% 50% 30% 10%
Wall 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
RCR Zonal Cavity Method - Effective Floor Cavity Reectance = 20%
Room Cavity Ratio
0 .41 .41 .41 .41 .40 .40 .40 .40 .38 .38 .38 .36 .36 .36 .35 .35 .35 .34
1 .39 .37 .36 .35 .38 .37 .36 .35 .35 .34 .34 .34 .33 .33 .33 .32 .32 .31
2 .36 .34 .33 .32 .36 .34 .32 .31 .33 .32 .30 .32 .31 .30 .31 .30 .29 .29
3 .34 .32 .30 .28 .34 .31 .30 .28 .30 .29 .28 .30 .28 .27 .29 .28 .27 .26
4 .32 .30 .27 .26 .32 .29 .27 .26 .28 .27 .25 .28 .26 .25 .27 .26 .25 .24
5 .31 .27 .25 .24 .30 .27 .25 .23 .26 .25 .23 .26 .24 .23 .25 .24 .23 .22
6 .29 .26 .23 .22 .28 .25 .23 .22 .25 .23 .21 .24 .23 .21 .24 .22 .21 .21
7 .27 .24 .21 .20 .27 .23 .21 .20 .23 .21 .20 .22 .21 .19 .22 .21 .19 .19
8 .26 .22 .20 .18 .25 .22 .20 .18 .21 .19 .18 .21 .19 .18 .21 .19 .18 .17
9 .24 .20 .18 .17 .24 .20 .18 .17 .20 .18 .16 .20 .18 .16 .19 .18 .16 .16
10 .23 .19 .17 .15 .22 .19 .17 .15 .18 .16 .15 .18 .16 .15 .18 .16 .15 .14
Determined in Accordance With Current IES Published Procedures
Luminaire Input Watts = 23.0
Tested According to IES Procedures. Test Distance Exceeds Five
Times the Greatest Luminous Opening of Luminaire.