Lightolier CFA2GPF217 or 317 Indoor Furnishings User Manual


 
Coffaire II Recessed Fluorescent CFA2GPF217 or 317
Page 2 of 2 Direct/Indirect 2' x 2' with Perforated Basket
Air Supply and Return, 2 Lamp or 3 Lamp, T8
Job Information Type:
Ordering Information
Explanation of Catalog Number. Example: CFA2GPF217120SO
Options/Accessories
Optional supply air slot cover: Order Catalog Number: CACS-2
Fusing: Internal fast blow fusing: SUFFIX: GLR.
Internal slow blow fusing: SUFFIX: GMF.
Drywall Kit: Order Catalog Number: FK92X2.
Electrical Wiring Options: Consult factory.
Chicago Plenum: SUFFIX: C.
Dust Shield: See Folio Number: OA50-20
Specifications
Performance: In an installation of 2 lamp 40W luminaires in a room cavity
ratio of 1, with reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not
be less than .64. To reduce glare the average brightness at 65° shall not exceed
1815 candelas per square meter. To control veiling reflections, luminaire output
in the 30°-90° zone shall not be less than 73.2%.
Materials: Chassis parts are die-formed code gauge steel.
Lamp Shield: 22 gauge steel perforated mesh lamp shield with white
acrylic overlay.
Specifications (continued)
Finish: Chassis exterior – soft white post painted polyester powder. Cavity
soft white post painted polyester powder. Reflector – soft white post painted
polyester powder, minimum 88% reflectance. Rust preventive undercoating.
Lamp Shield –white.
Electrical: Thermally protected class “P’ ballast C.B.M. approved, non PCB. If
K.O. is within 3" of ballast, use wire suitable for at least 90°. UL Listed for damp
locations.
Labels: I.B.E.W./UL and ULc Listed.
Options:
Add appropriate
suffix to catalog
no., ie: (GLR)
Coffaire II:
Direct/
Indirect:
Recessed
with Perforated
Mesh Shield
A
Body Style:
A = AirSupply
and Return
2
Fixture
Width
G
Ceiling Type:
Standard Grid
P
Perforated
Lamp
Shield
17
Lamp:
(By Others)
17=T8
(Nominal 24")
F
Flat
White
Reflector
Lamp
Quantity
2=2 Lamp
3=3 Lamp
Ballast Type:
<20THD <10THD
1 or2 Lamp Elec.T8 SO * H
I *
1-3 LampElec. T8 O3 * H3 *
LOL DimmingT8 PS*
*Instant Start Standard
Other dimmingoptions. Consult factory.
NOTE: For T8UNV, you mustuse H
I
,H3, BallastCode.
Model No. CFA2GPF217120SO
LER = FP - 50.2 IW - 30.08 BF - 0.93
Comparative yearly lighting energy cost per
1000 lumens = $4.78
Report Number: G2004248
Catalog Number: CFA2GPF217120SO
Lamps: F017/41K
Luminaire: Coffaire 2'x2' with perforated
basket
Ballast: Triad C240SI120
Report is based on 1350 Lumens per lamp.
Efficiency: 61.7%
CIE Type-Direct-Indirect
Plane: 0-Deg 90-Deg
Spacing Criteria: 1.2 1.4
Shielding Angles: 55 65
Plane: 0-Deg 90-Deg
Luminous Length: 22.920 22.920
CANDELA DISTRIBUTION
0
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. 0-DEG. 45-DEG. 90-DEG.
45 1443. 1668. 1856.
55 1301. 1656. 1928.
65 1089. 1605. 1815.
75 889. 1037. 1219.
85 508. 541. 575.
LUMINANCE DATA IN CANDELA/SQ.METER
COEFFICIENTS OFUTILIZATION
ZONAL CAVITY METHOD. EFFECTIVE
FLOOR CAVITY REFLECTANCE 0.20
0
RC 80 50 30
RW 70 50 30 50 30 10 50 30 10
01 67 64 62 60 58 57 58 56 55
02 61 56 52 53 49 47 51 48 46
03 56 49 44 46 42 39 45 41 38
04 51 43 38 41 37 33 40 36 33
05 47 39 33 37 32 29 35 31 28
06 43 35 29 33 28 25 32 28 25
07 40 32 26 30 25 22 29 25 22
08 37 29 23 27 23 20 27 23 19
09 35 26 21 25 21 18 25 20 18
10 32 24 19 23 19 16 23 19 16
ZONE LUMENS % LAMP %FIXT
00-030 446 16.5 26.8
00-040 736 27.3 44.2
00-060 1327 49.1 79.7
00-090 1665 61.7 100.0
90-180 0000 0.0 000.0
00-180 1665 61.7 100.0
ZONAL LUMENSUMMARY
Model No. CFA2GPF317120O3
LER = FP - 48.7 IW - 46.5 BF - 1.00
Comparative yearly lighting energy cost per
1000 lumens = $0.00
Report Number: G2004249
Catalog Number: CFA2GPF317120O3
Lamps: F017/41K
Luminaire: Coffaire with perforated
basket
Ballast: Triad B332I120
Report is based on 1350 Lumens per lamp.
Efficiency: 55.9%
CIE Type-Direct-Indirect
Plane: 0-Deg 90-Deg
Spacing Criteria: 1.2 1.3
Shielding Angles: 55 65
Plane: 0-Deg 90-Deg
Luminous Length: 22.920 22.920
0.0 45.0 90.0 FLUX
0 800 800 800
5 794 796 798 76
15 754 766 780 217
25 684 712 741 329
35 591 638 682 399
45 476 544 600 417
55 346 431 493 380
65 208 300 338 283
75 103 133 147 137
85 19 22 23 27
90 000
CANDELA DISTRIBUTION
0
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. 0-DEG. 45-DEG. 90-DEG.
45 1985. 2269. 2503.
55 1779. 2216. 2535.
65 1452. 2094. 2359.
75 1174. 1516. 1675.
85 643. 745. 778.
LUMINANCE DATA INCANDELA/SQ. METER
COEFFICIENTS OFUTILIZATION
ZONAL CAVITY METHOD. EFFECTIVE
FLOOR CAVITY REFLECTANCE 0.20
0
RC 80 50 30
RW 70 50 30 50 30 10 50 30 10
01 61 58 56 55 53 51 53 51 50
02 56 51 47 48 45 42 46 44 42
03 51 45 40 42 39 36 41 38 35
04 46 40 35 37 33 30 36 33 30
05 43 35 30 34 29 26 32 29 23
06 39 32 27 30 26 23 29 26 23
07 36 29 24 27 23 20 27 23 20
08 34 26 22 25 21 18 24 21 18
09 32 24 20 23 19 16 23 19 16
10 30 22 18 21 17 15 21 17 15
ZONE LUMENS % LAMP %FIXT
00-030 621 15.3 27.4
00-040 1020 25.2 45.1
00-060 1817 44.9 80.3
00-090 2264 55.9 100.0
90-180 0000 00.0 000.0
00-180 2264 55.9 100.0
ZONAL LUMEN SUMMARY
Lightolier a Genlyte company www.lightolier.com
Technical Information: (978) 657-7600 • Fax (978) 658-0595
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2007 a Genlyte company
Section 5/Folio M15-36
Voltage:
120, 277or
UNV=120-277
0.0 45.0 90.0 FLUX
0 572 572 572
5 569 570 570 54
15 541 550 560 155
25 492 515 537 237
35 426 465 500 290
45 346 400 445 307
55 253 322 375 283
65 156 230 260 215
75 78 91 107 104
85 15 16 17 20
90 000
CF
Standard CoffaireII
CN
For NYCCode –Local 3Manufactured