Lightolier C6CS-C6T6VM Indoor Furnishings User Manual


 
Calculite
®
HID Surface Cylinder C6CS-C6T6VM
Page 2 of 2 6" Aperture, Ceramic Metal Halide, T6 Medium Beam
Lightolier a Genlyte Thomas Company www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2004 Genlyte Thomas Group LLC (Lightolier Division) • A0504
Job Information Type:
CEILING 80% 70% 50% 30%
WALL 70 50 30 10 50 10 50 10 50 10 0
RCR
0 .77 .77 .77 .77 .75 .75 .72 .72 .69 .69 .64
1 .74 .72 .71 .69 .71 .68 .68 .66 .66 .64 .61
2 .71 .68 .66 .64 .67 .63 .65 .62 .63 .61 .58
3 .68 .64 .61 .59 .63 .59 .62 .58 .60 .57 .55
4 .65 .61 .58 .55 .60 .55 .59 .54 .57 .54 .52
5 .62 .57 .54 .52 .57 .51 .56 .51 .55 .50 .49
6 .59 .54 .51 .49 .54 .48 .53 .48 .52 .48 .47
7 .56 .51 .48 .45 .51 .45 .50 .45 .49 .45 .44
8 .54 .48 .45 .42 .48 .42 .47 .42 .47 .42 .41
9 .51 .46 .42 .40 .45 .40 .45 .39 .44 .39 .38
10 .49 .43 .39 .37 .43 .37 .42 .37 .42 .37 .36
LUMINAIRE INPUT WATTS = 44
ANGLE MEAN CP LUMENS
0 2382
5 2347 223
10 2265
15 2086 581
20 1766
25 1385 648
30 1062
35 836 518
40 566
45 248 209
50 20
55 3 6
60 0
65 0 0
70 0
75 0 0
80 0
85 0 0
90 0
ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS % LAMP %LUMINAIRE
0-30 1452 42.71 66.44
0-40 1970 57.94 90.14
0-60 2185 64.28 99.99
0-90 2185 64.28 100
40-90 215 6.34 9.86
60-90 0 0 0.01
90-180 0 0 0
0-180 2185 64.28 100
39W T6 PHILIPS CERAMIC MH LAMP, LUMEN RATING = 3400 LMS, AROMAT ELECTRONIC BALLAST, CL FINISH TRIM
Coefficients of Utilization
LUMINANCE SUMMARY CD. / SQ. M.
ANGLE MEAN CD/SQ M
45 21039
55 301
65 5
75 19
85 0
** EFFICIENCY = 64.3% ** CERTIFIED TEST REPORT NO. 2337FR, DATE: OCT 24, 2003
SC = 0.9 COMPUTED BY LSI PROGRAM **TEST-LITE**
CANDLEPOWER DISTRIBUTION
CEILING 80% 70% 50% 30%
WALL 70 50 30 10 50 10 50 10 50 10 0
RCR
0 .76 .76 .76 .76 .74 .74 .70 .70 .67 .67 .63
1 .72 .71 .69 .68 .70 .67 .67 .65 .65 .63 .60
2 .69 .67 .65 .62 .66 .62 .63 .60 .62 .59 .57
3 .66 .63 .60 .58 .62 .57 .60 .57 .59 .56 .54
4 .64 .59 .56 .54 .59 .54 .57 .53 .56 .52 .51
5 .61 .56 .53 .50 .55 .50 .54 .50 .53 .49 .48
6 .58 .53 .50 .47 .52 .47 .51 .47 .51 .46 .45
7 .55 .50 .46 .44 .49 .44 .49 .44 .48 .43 .42
8 .53 .47 .43 .41 .46 .41 .46 .41 .45 .41 .40
9 .50 .44 .41 .38 .44 .38 .43 .38 .43 .38 .37
10 .47 .41 .38 .36 .41 .36 .41 .35 .40 .35 .34
LUMINAIRE INPUT WATTS = 78
ANGLE MEAN CP LUMENS
0 4188
5 4141 394
10 4047
15 3813 1062
20 3312
25 2664 1244
30 2115
35 1667 1031
40 1114
45 479 408
50 32
55 3 8
60 0
65 0 0
70 0
75 0 0
80 0
85 0 0
90 0
70W T6 PHILIPS CERAMIC MH LAMP, LUMEN RATING = 6600 LMS, AROMAT ELECTRONIC BALLAST, CL FINISH TRIM
Coefficients of Utilization
LUMINANCE SUMMARY CD. / SQ. M.
ANGLE MEAN CD/SQ M
45 40627
55 293
65 0
75 0
85 0
** EFFICIENCY = 62.8% ** CERTIFIED TEST REPORT NO. 2335FR, DATE: OCT 14, 2003
SC = 0.9 COMPUTED BY LSI PROGRAM **TEST-LITE**
CANDLEPOWER DISTRIBUTION
ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS % LAMP %LUMINAIRE
0-30 2700 40.92 65.12
0-40 3731 56.53 89.97
0-60 4147 62.84 100
0-90 4147 62.84 100
40-90 416 6.3 10.03
60-90 0 0 0
90-180 0 0 0
0-180 4147 62.84 100
Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%
Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%
1,250
30°
60°
30°
60°
625
1,875
2,500
2,000
1,000
3,000
4,000