Lightolier C4CIN Indoor Furnishings User Manual


 
Lightolier is a Philips group brand
Job Information Type:
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2008 Philips Group • F0708
Calculite
®
HID Surface Cylinder C4CIN
Page 1 of 2 T4.5 Ceramic Metal Halide, Inno
250
125
375
500
500
250
750
1,000
30°
60°
30°
60°
20W T4.5 G.E. CERAMIC MH, LUMEN RATING = 1700 LMS., AROMAT 20W ELECTRONIC BALLAST
ANGLE MEAN CP LUMENS
0 492
5 487 46
10 472
15 441 124
20 392
25 331 153
30 268
35 198 125
40 129
45 86 71
50 66
55 59 54
60 56
65 52 52
70 48
75 43 45
80 37
85 32 35
90 26
ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS % LAMP %LUMINAIRE
0-30 322 19 45.83
0-40 447 26.33 63.51
0-60 572 33.68 81.25
0-90 704 41.45 100
40-90 257 15.12 36.49
60-90 132 7.77 18.75
90-180 0 0 0
0-180 704 41.45 100
LUMINANCE SUMMARY - CD. / SQ. M.
ANGLE MEAN CD/SQ M
45 6702
55 5702
65 6829
75 9096
85 20303
** EFFICIENCY = 41.5% ** CERTIFIED TEST REPORT NO. 2615FR DATE: MAY 7, 2004
SC..9 COMPUTED BY LSI PROGRAM **TEST-LITE**
CEILING 80% 70% 50% 30%
WALL 70 50 30 10 50 10 50 10 50 10 0
RCR
0 .49 .49 .49 .49 .48 .48 .46 .46 .44 .44 .41
1 .46 .44 .42 .41 .43 .40 .41 .39 .40 .38 .36
2 .42 .40 .37 .35 .39 .35 .37 .34 .36 .33 .32
3 .40 .36 .33 .31 .35 .31 .34 .30 .33 .30 .29
4 .37 .33 .30 .28 .33 .28 .32 .28 .31 .27 .26
5 .35 .31 .28 .25 .30 .25 .29 .25 .29 .25 .24
6 .33 .29 .25 .23 .28 .23 .27 .23 .27 .23 .22
7 .31 .26 .23 .21 .26 .21 .26 .21 .25 .21 .20
8 .29 .25 .22 .20 .24 .20 .24 .20 .23 .19 .19
9 .28 .23 .20 .18 .23 .18 .22 .18 .22 .18 .17
10 .26 .22 .19 .17 .21 .17 .21 .17 .21 .17 .16
LUMINAIRE INPUT WATTS = 23
Coefficients of Utilization
Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%
39W T4.5 PHILIPS CERAMIC MH, LUMEN RATING = 3300 LMS., AROMAT 39W ELECTRONIC BALLAST
ANGLE MEAN CP LUMENS
0 1018
5 1007 96
10 974
15 905 254
20 801
25 678 313
30 549
35 404 254
40 262
45 174 144
50 133
55 121 110
60 114
65 107 106
70 98
75 87 92
80 77
85 66 72
90 54
ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS % LAMP %LUMINAIRE
0-30 662 20.09 46.03
0-40 916 27.79 63.67
0-60 1170 35.47 81.28
0-90 1440 43.64 100
40-90 523 15.85 36.33
60-90 269 8.17 18.72
90-180 0 0 0
0-180 1440 43.64 100
LUMINANCE SUMMARY - CD. / SQ. M.
ANGLE MEAN CD/SQ M
45 13544
55 11586
65 13906
75 18535
85 41710
** EFFICIENCY = 43.6% ** CERTIFIED TEST REPORT NO. 2614FR DATE: MAY 5, 2004
SC = .9 COMPUTED BY LSI PROGRAM **TEST-LITE**
CEILING 80% 70% 50% 30%
WALL 70 50 30 10 50 10 50 10 50 10 0
RCR
0 .52 .52 .52 .52 .51 .51 .48 .48 .46 .46 .44
1 .48 .46 .44 .43 .45 .42 .43 .41 .42 .40 .38
2 .45 .42 .39 .37 .41 .37 .39 .36 .38 .35 .33
3 .42 .38 .35 .33 .37 .32 .36 .32 .35 .31 .30
4 .39 .35 .32 .30 .35 .29 .33 .29 .33 .29 .27
5 .37 .32 .29 .27 .32 .27 .31 .26 .30 .26 .25
6 .35 .30 .27 .25 .30 .24 .29 .24 .28 .24 .23
7 .33 .28 .25 .23 .28 .22 .27 .22 .26 .22 .21
8 .31 .26 .23 .21 .26 .21 .25 .21 .25 .20 .20
9 .29 .24 .21 .19 .24 .19 .24 .19 .23 .19 .18
10 .28 .23 .20 .18 .22 .18 .22 .18 .22 .18 .17
LUMINAIRE INPUT WATTS = 44
Coefficients of Utilization
Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%