Lightolier C3MRPD Indoor Furnishings User Manual


 
Job Informationv Type:
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2008 Philips Group •F0408
Calculite
®
Evolution Pinhole Downlight C3MRPD
Page 2 of 2 1 1/4" Aperture, MR16 (12V)
Lightolier is a Philips group brand
Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%
ANGLE MEAN CP
LUMENS
0 1524
5 1350 126
10 1069
15 813 225
20 485
25 139 91
30 24
35 7 6
40 1
45 0 0
50 0
55 0 0
60 0
65 0 0
70 0
75 0 0
80 0
85 0 0
90 0
37W MR16 IR - 40° Flood Sylvania Halogen Lamp, Lumen Rating = 840 LMS, 120V Electronic Transformer
LUMINANCE SUMMARY CD. / SQ.M.
ANGLE MEAN CD/SQ M
45 0
55 0
65 0
75 0
85 0
** EFFICIENCY = 53.5% ** CERTIFIED TEST REPORT NO. 2739FR DATE: SEPT 24, 2004
COMPUTED BY LSI PROGRAM **TEST-LITE**
CANDLEPOWER DISTRIBUTION
CEILING 80% 70% 50% 30%
WALL 70 50 30 10 50 10 50 10 50 10 0
RCR
0 .64 .64 .64 .64 .62 .62 .59 .59 .57 .57 .54
1 .62 .61 .60 .60 .60 .59 .58 .57 .56 .55 .53
2 .60 .59 .58 .57 .58 .56 .56 .55 .55 .54 .52
3 .59 .57 .56 .54 .56 .54 .55 .53 .54 .52 .51
4 .58 .56 .54 .53 .55 .52 .54 .52 .53 .51 .50
5 .57 .54 .52 .51 .54 .51 .53 .50 .52 .50 .49
6 .56 .53 .51 .50 .53 .50 .52 .49 .51 .49 .48
7 .54 .52 .50 .49 .51 .48 .51 .48 .50 .48 .47
8 .53 .50 .49 .48 .50 .47 .50 .47 .49 .47 .46
9 .52 .49 .48 .46 .49 .46 .49 .46 .48 .46 .46
10 .51 .48 .47 .45 .48 .45 .48 .45 .48 .45 .45
LUMINAIRE INPUT WATTS = 38
Coefficients of Utilization
SC = .5
ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS % LAMP %LUMINAIRE
0-30 442 52.70 98.47
0-40 448 53.42 99.81
0-60 449 53.51 99.97
0-90 449 53.52 100.00
40-90 0 0.10 0.19
60-90 0 0.01 0.03
90-180 0 0.00 0.00
0-180 449 53.52 100.00
Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%
ANGLE MEAN CP
LUMENS
0 1391
5 1364 128
10 1234
15 944 259
20 539
25 166 104
30 31
35 7 7
40 2
45 0 0
50 0
55 0 0
60 0
65 0 0
70 0
75 0 0
80 0
85 0 0
90 0
50W MR16 IR - 40° Flood GE Halogen Lamp, Lumen Rating = 800 LMS, 120V Electronic Transformer
LUMINANCE SUMMARY CD. / SQ.M.
ANGLE MEAN CD/SQ M
45 0
55 0
65 0
75 0
85 0
** EFFICIENCY = 62.5% ** CERTIFIED TEST REPORT NO. 2720FR DATE: SEPT 5, 2004
COMPUTED BY LSI PROGRAM **TEST-LITE**
CANDLEPOWER DISTRIBUTION
CEILING 80% 70% 50% 30%
WALL 70 50 30 10 50 10 50 10 50 10 0
RCR
0 .74 .74 .74 .74 .73 .73 .69 .69 .66 .66 .62
1 .72 .71 .70 .70 .70 .68 .68 .66 .65 .64 .62
2 .70 .69 .67 .66 .68 .65 .66 .64 .64 .63 .60
3 .69 .67 .65 .63 .66 .63 .64 .62 .63 .61 .60
4 .67 .65 .63 .61 .64 .61 .63 .60 .62 .60 .58
5 .66 .63 .61 .59 .62 .59 .61 .59 .61 .58 .57
6 .65 .62 .59 .58 .61 .58 .60 .57 .60 .57 .56
7 .63 .60 .58 .56 .60 .56 .59 .56 .58 .56 .55
8 .62 .59 .57 .56 .58 .55 .58 .55 .57 .55 .54
9 .61 .57 .55 .54 .57 .54 .57 .54 .56 .53 .53
10 .59 .56 .54 .53 .56 .53 .55 .53 .55 .52 .52
LUMINAIRE INPUT WATTS = 51
Coefficients of Utilization
SC = .6
ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS % LAMP %LUMINAIRE
0-30 491 61.43 98.34
0-40 498 62.36 99.83
0-60 499 62.45 99.97
0-90 499 62.47 100.00
40-90 0 0.11 0.17
60-90 0 0.02 0.03
90-180 0 0.00 0.00
0-180 499 62.47 100.00
Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%
ANGLE MEAN CP
LUMENS
0 2041
5 1808 169
10 1433
15 1089 302
20 650
25 186 122
30 33
35 9 8
40 2
45 1 1
50 1
55 1 1
60 0
65 0 0
70 0
75 0 0
80 0
85 0 0
90 0
50W MR16 IR - 40° Flood Sylvania Halogen Lamp, Lumen Rating = 1125 LMS, 120V Electronic Transformer
500
1000
1500
2000
30˚
60˚
90˚
LUMINANCE SUMMARY CD. / SQ.M.
ANGLE MEAN CD/SQ M
45 0
55 0
65 0
75 0
85 0
** EFFICIENCY = 53.6% ** CERTIFIED TEST REPORT NO. 2721FR DATE: SEPT 5, 2004
COMPUTED BY LSI PROGRAM **TEST-LITE**
CANDLEPOWER DISTRIBUTION
CEILING 80% 70% 50% 30%
WALL 70 50 30 10 50 10 50 10 50 10 0
RCR
0 .64 .64 .64 .64 .62 .62 .60 .60 .57 .57 .54
1 .62 .61 .60 .60 .60 .59 .58 .57 .56 .55 .53
2 .60 .59 .58 .57 .58 .56 .56 .55 .55 .54 .52
3 .59 .57 .56 .54 .56 .54 .55 .53 .54 .52 .51
4 .58 .56 .54 .53 .55 .52 .54 .52 .51 .51 .50
5 .57 .54 .52 .51 .54 .51 .53 .50 .52 .50 .49
6 .56 .53 .51 .50 .53 .50 .52 .49 .51 .49 .48
7 .54 .52 .50 .49 .51 .48 .51 .48 .50 .48 .47
8 .53 .50 .49 .48 .50 .47 .50 .47 .49 .47 .46
9 .52 .49 .48 .46 .49 .46 .49 .46 .48 .46 .46
10 .51 .48 .47 .45 .48 .45 .48 .45 .48 .45 .45
LUMINAIRE INPUT WATTS = 51
Coefficients of Utilization
SC = .5
ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS % LAMP %LUMINAIRE
0-30 593 52.72 98.39
0-40 601 53.45 99.75
0-60 602 53.57 99.97
0-90 602 53.59 100.00
40-90 1 0.13 0.25
60-90 0 0.02 0.03
90-180 0 0.00 0.00
0-180 602 53.59 100.00
30˚
60˚
375˚
750˚
1125˚
1500˚
30˚
60˚
400˚
800˚
1200˚
1600˚
30˚
60˚
500˚
1000˚
1500˚
2000˚