Lightolier C3MRGD Indoor Furnishings User Manual


 
Lightolier a Genlyte company www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2007 Genlyte Group LLC • D1107
Job Information Type:
Calculite
®
Evolution Glasslite Downlight C3MRGD
Page 2 of 2 3" Aperture, MR16 (12V)
Spec. Sheet
C3MRGD
Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%
ANGLE MEAN CP
LUMENS
0 5551
5 3854 345
10 1184
15 310 138
20 141
25 48 30
30 22
35 8 7
40 5
45 2 2
50 1
55 2 1
60 1
65 0 0
70 0
75 0 0
80 0
85 0 0
90 0
50W MR16 - 15° SPOT GE HALOGEN LAMP, LUMEN RATING = 750 LMS, 120V ELECTRONIC TRANSFORMER
LUMINANCE SUMMARY CD. / SQ. M.
ANGLE MEAN CD/SQ M
45 640
55 750
65 104
75 170
85 0
** EFFICIENCY = 69.7% ** CERTIFIED TEST REPORT NO. 2724FR DATE: SEP 7, 2004
COMPUTED BY LSI PROGRAM **TEST-LITE**
CANDLEPOWER DISTRIBUTION
CEILING 80% 70% 50% 30%
WALL 70 50 30 10 50 10 50 10 50 10 0
RCR
0 .83 .83 .83 .83 .81 .81 .77 .77 .74 .74 .70
1 .81 .80 .79 .78 .79 .77 .76 .75 .73 .73 .69
2 .79 .79 .76 .75 .76 .74 .74 .73 .73 .71 .69
3 .78 .76 .74 .73 .75 .72 .73 .71 .72 .70 .68
4 .77 .74 .72 .71 .74 .70 .72 .70 .71 .69 .68
5 .75 .73 .71 .69 .72 .69 .71 .69 .70 .68 .67
6 .74 .72 .70 .68 .71 .68 .70 .68 .70 .67 .66
7 .73 .71 .69 .67 .70 .67 .69 .67 .69 .66 .66
8 .73 .70 .68 .67 .69 .66 .69 .66 .68 .66 .65
9 .72 .69 .67 .66 .68 .66 .68 .65 .68 .65 .65
10 .71 .68 .66 .65 .68 .65 .67 .65 .67 .65 .64
LUMINAIRE INPUT WATTS = 51
Coefficients of Utilization
SC = .2
ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS % LAMP %LUMINAIRE
0-30 512 68.32 97.99
0-40 518 66.20 99.25
0-60 522 69.64 99.89
0-90 522 69.72 100.00
40-90 3 0.52 0.75
60-90 0 0.08 0.11
90-180 0 0.00 0.00
0-180 522 69.72 100.00
Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%
ANGLE MEAN CP
LUMENS
0 1816
5 1629 150
10 1213
15 792 231
20 460
25 194 107
30 74
35 27 21
40 8
45 5 4
50 4
55 3 3
60 3
65 2 2
70 2
75 1 1
80 1
85 0 0
90 0
50W MR16 - 25° NARROW FLOOD GE HALOGEN LAMP, LUMEN RATING = 800 LMS, 120V ELECTRONIC TRANSFORMER
LUMINANCE SUMMARY CD. / SQ. M.
ANGLE MEAN CD/SQ M
45 1483
55 1270
65 1241
75 1079
85 351
** EFFICIENCY = 65.1% ** CERTIFIED TEST REPORT NO. 2817FR DATE: SEP 5, 2004
COMPUTED BY LSI PROGRAM **TEST-LITE**
CANDLEPOWER DISTRIBUTION
CEILING 80% 70% 50% 30%
WALL 70 50 30 10 50 10 50 10 50 10 0
RCR
0 .77 .77 .77 .77 .76 .76 .72 .72 .69 .69 .65
1 .75 .74 .73 .72 .73 .71 .70 .69 .68 .67 .64
2 .73 .71 .70 .68 .70 .67 .68 .66 .66 .64 .62
3 .71 .69 .67 .65 .68 .65 .66 .64 .65 .63 .61
4 .70 .67 .64 .63 .66 .62 .65 .62 .64 .61 .60
5 .68 .65 .62 .60 .64 .60 .63 .60 .62 .59 .58
6 .66 .63 .61 .59 .62 .59 .62 .58 .61 .58 .57
7 .65 .61 .59 .57 .61 .57 .60 .57 .59 .56 .56
8 .63 .60 .57 .56 .59 .56 .59 .55 .58 .55 .54
9 .62 .58 .56 .54 .58 .54 .57 .54 .57 .54 .53
10 .61 .57 .55 .53 .57 .53 .56 .53 .56 .53 .52
LUMINAIRE INPUT WATTS = 51
Coefficients of Utilization
SC = .5
ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS % LAMP %LUMINAIRE
0-30 487 60.97 93.72
0-40 509 63.64 97.83
0-60 516 64.55 99.23
0-90 520 65.05 100.00
40-90 11 1.41 2.17
60-90 4 0.50 0.77
90-180 0 0.00 0.00
0-180 520 65.05 100.00
Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%
ANGLE MEAN CP
LUMENS
0 1425
5 1388 130
10 1256
15 1006 275
20 616
25 182 118
30 42
35 17 13
40 8
45 4 3
50 3
55 2 2
60 2
65 1 1
70 0
75 0 0
80 0
85 0 0
90 0
50W MR16 - 40° FLOOD GE HALOGEN LAMP, LUMEN RATING = 800 LMS, 120V ELECTRONIC TRANSFORMER
LUMINANCE SUMMARY CD. / SQ. M.
ANGLE MEAN CD/SQ M
45 1164
55 864
65 616
75 0
85 0
** EFFICIENCY = 68% ** CERTIFIED TEST REPORT NO. 2722FR DATE: SEP 5, 2004
COMPUTED BY LSI PROGRAM **TEST-LITE**
CANDLEPOWER DISTRIBUTION
CEILING 80% 70% 50% 30%
WALL 70 50 30 10 50 10 50 10 50 10 0
RCR
0 .81 .81 .81 .81 .79 .79 .76 .76 .72 .72 .66
1 .79 .78 .77 .75 .76 .74 .73 .72 .71 .70 .67
2 .76 .75 .73. 71 .73 .71 .71 .69 .69 .68 .65
3 .75 .72 .70 .68 .71 .68 .70 .67 .68 .66 .64
4 .73 .70 .68 .66 .69 .66 .68 .65 .67 .64 .63
5 .71 .68 .65 .64 .67 .63 .66 .63 .65 .62 .61
6 .70 .66 .64 .62 .66 .62 .65 .62 .64 .61 .60
7 .68 .64 .62 .60 .64 .60 .63 .60 .63 .60 .59
8 .67 .63 .60 .59 .62 .59 .62 .58 .61 .58 .57
9 .65 .61 .59 .57 .61 .57 .60 .57 .60 .57 .56
10 .64 .60 .58 .56 .60 .56 .59 .56 .59 .56 .55
LUMINAIRE INPUT WATTS = 51
Coefficients of Utilization
SC = .6
ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS % LAMP %LUMINAIRE
0-30 523 65.48 96.34
0-40 537 67.14 98.77
0-60 542 67.82 98.77
0-90 543 67.97 100.00
40-90 6 0.83 1.23
60-90 1 0.16 0.23
90-180 0 0.00 0.00
0-180 543 67.97 100.00
30˚
60˚
500˚
1000˚
1500˚
2000˚
30˚
60˚
1400˚
2800˚
4200˚
5600˚
30˚
60˚
375˚
750˚
1125˚
1500˚