Job Information Type:
Performance
Candlepower Curve Candlepower Summary Coefficients of Utilization
Report No: 9900043
Lamps: F32T8
Lumens per Lamp: 2950
Efficiency: 69.8%
Up: 89.1% Down: 10.9%
Zonal Lumen Summary
ZONE LUMENS %BARE LAMP %LUMINAIRE
0
10
20
30
40
50
60
70
80
90
100
110
120
130
140
150
160
170
180
1300
975
650
325
190
200
210
220
230
240
250
260
270
280
290
300
310
320
330
340
350
CANDLEPOWER SUMMARY
ZONE CANDLEPOWER
DEG. 0 45 90 135 180
180 752 752 752 752 752
175 784 772 748 749 750
165 866 816 723 734 744
155 956 854 675 707 736
145 1065 885 606 667 726
135 1167 908 517 624 709
125 1260 915 410 574 691
115 1164 926 292 527 639
105 749 689 162 414 467
95 272 248 41 122 123
90 29 27 3 6 5
85 22 23 8 4 3
75 35 53 18 4 4
65 122 127 26 6 4
55 218 199 45 19 8
45 296 230 70 23 25
35 305 224 96 17 21
25 263 213 120 11 11
15 221 196 140 28 8
5 180 175 153 110 93
0 155 155 155 155 155
COEFFICIENTS OF UTILIZATION
% EFFECTIVE CEILING CAVITY REFLECTANCE
80 70 50
% WALL REFLECTANCE
50 30 10 50 30 10 50 30 10
0 68 68 68 59 59 59 43 43 43
1 59 56 54 51 49 47 37 36 35
2 51 47 44 45 41 39 32 30 28
3 45 40 36 39 35 32 28 26 24
4 39 34 30 34 30 27 25 22 20
5 35 30 26 30 26 23 22 19 17
6 31 26 22 27 23 19 20 17 14
7 28 23 19 24 20 17 18 15 12
8 25 20 16 22 17 14 16 13 11
9 23 18 14 20 16 13 14 11 9
10 20 16 13 18 14 11 13 10 8
ZONAL LUMEN SUMMARY
ZONE LUMENS % BARE LAMP %LUMINAIRE
0-90
90-180
0-180
4118
3670
448 10.9
89.1
100.0
7.6
62.2
69.8
COEFFICIENTS OF UTILIZATION
% EFFECTIVE CEILING CAVITY REFLECTANCE
80 70 50
% WALL REFLECTANCE
50 30 10 50 30 10 50 30 10
0 68 68 68 59 59 59 43 43 43
1 59 56 54 51 49 47 37 36 35
2 51 47 44 45 41 39 32 30 28
3 45 40 36 39 35 32 28 26 24
4 39 34 30 34 30 27 25 22 20
5 35 30 26 30 26 23 22 19 17
6 31 26 22 27 23 19 20 17 14
7 28 23 19 24 20 17 18 15 12
8 25 20 16 22 17 14 16 13 11
9 23 18 14 20 16 13 14 11 9
10 20 16 13 18 14 11 13 10 8
ZONAL LUMEN SUMMARY
ZONE LUMENS % BARE LAMP %LUMINAIRE
0-90
90-180
0-180
4118
3670
448 10.9
89.1
100.0
7.6
62.2
69.8
Module Lengths & Mounting Distances
Run Configuration
Run
Length
4’
Module
8’
Module
12’
Module
Joiner End Set Mount
Power
Mount*
4’ run 1 1 1 1
8’ run 1 1 1 1
12’ run
1 1 1 1
16’ run
2 1 1 2 1
20’ run 1 1 1 1 2 1
24’ run 2 1 1 2 1
28’ run 2 1 2 1 3 1
32’ run 1 2 2 1 3 1
-ODULE,ENGTH
-OUNTING$ISTANCE
-ODULE,ENGTH-OUNTING$ISTANCE
-ODULE,ENGTH-OUNTING$ISTANCE
@
@
@
Note: Shaded area indicates locations of emergency sections (emergency wiring
controls all lamps or optional battery pack controls one or two lamps).
*Note: Additional power mounts may be required for some runs with T5 HO
lamping options, longer runs, and runs with wiring options that are more complex.
Please consult factory for assistance.
Joiner
BSLEWW = wall mount standard white
Dust Cover
End Set
BSLJW = wall mount joiner
BSLDCW = 4’ wall mount dust cover
System Components & Accessories
Non-Power Wall Mount Power Wall Mount
BSLWP1 = 1-power mount
BSLWP2 = 2-power mount
BSLWN = non-power wall mount