Lightolier Baselyte-BSL7 Indoor Furnishings User Manual


 
Lighting Systems Baselyte-BSL7
Page 2 of 8 4 Light T5 HO Direct/Indirect
Lightolier a Genlyte Company www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2005 Genlyte Group LLC • 0205 Rev.1
Job Information Type:
Performance
Candlepower Curve Candlepower Summary Coefficients of Utilization
-ODULE,ENGTH
-OUNTING$ISTANCE
-ODULE,ENGTH-OUNTING$ISTANCE
-ODULE,ENGTH-OUNTING$ISTANCE
@
@
@
Module Lengths & Mounting Distances
Joiner
BSLESW = suspended standard white
End Set
BSLJS = suspended joiner
System Components & Accessories
Run Configuration
Report No: 2101637
Lamps: F54T5
Lumens per Lamp: 4650
Efficiency: 88.5%
Up: 87.0% Down: 13.0%
Run
Length
4’
Module
8’
Module
12’
Module
Joiner End Set Mount
Power
Mount*
4’ run 1 1 1 1
8’ run 1 1 1 1
12’ run
1 1 1 1
16’ run
2 1 1 2 1
20’ run 1 1 1 1 2 1
24’ run 2 1 1 2 1
28’ run 2 1 2 1 3 1
32’ run 1 2 2 1 3 1
Zonal Lumen Summary
ZONE LUMENS %BARE LAMP %LUMINAIRE






















CANDLEPOWER SUMMARY
ZONE CANDLEPOWER
DEG. 0 22.5 45 67.5 90
180 3780 3780 3780 3780 3780
175 3757 3762 3776 3787 3790
165 3617 3654 3726 3782 3804
155 3361 3443 3610 3745 3800
145 2994 3135 3442 3704 3795
135 2527 2752 3231 3577 3701
125 1981 2325 2930 3286 3418
115 1384 1867 2442 2658 2768
105 742 1261 1585 1586 1679
95 166 337 474 409 489
90 11 47 67 76 77
85 34 51 74 82 86
75 84 94 110 120 125
65 151 207 181 172 177
55 313 347 319 261 265
45 513 446 495 456 453
35 712 621 610 638 643
25 896 849 715 689 710
15 1044 1064 978 895 891
5 1135 1136 1152 1160 1162
0 1144 1144 1144 1144 1144
COEFFICIENTS OF UTILIZATION
% EFFECTIVE CEILING CAVITY REFLECTANCE
80 70 50
% WALL REFLECTANCE
50 30 10 50 30 10 50 30 10
0 87 87 87 76 76 76 55 55 55
1 75 72 69 66 63 61 48 46 45
2 66 61 56 58 53 50 42 39 37
3 58 52 47 51 46 42 37 34 31
4 51 44 39 45 39 35 33 29 26
5 45 38 34 40 34 30 29 26 23
6 40 34 29 35 30 26 26 22 20
7 36 30 25 32 26 22 24 20 17
8 33 26 22 29 23 20 21 18 15
9 30 23 19 26 21 17 19 16 13
10 27 21 17 24 19 15 18 14 12
ZONAL LUMEN SUMMARY
ZONE LUMENS % BARE LAMP %LUMINAIRE
0-90
90-180
0-180
16458
14324
2134 13.0
87.0
100.0
11.5
77.0
88.5
COEFFICIENTS OF UTILIZATION
% EFFECTIVE CEILING CAVITY REFLECTANCE
80 70 50
% WALL REFLECTANCE
50 30 10 50 30 10 50 30 10
0 87 87 87 76 76 76 55 55 55
1 75 72 69 66 63 61 48 46 45
2 66 61 56 58 53 50 42 39 37
3 58 52 47 51 46 42 37 34 31
4 51 44 39 45 39 35 33 29 26
5 45 38 34 40 34 30 29 26 23
6 40 34 29 35 30 26 26 22 20
7 36 30 25 32 26 22 24 20 17
8 33 26 22 29 23 20 21 18 15
9 30 23 19 26 21 17 19 16 13
10 27 21 17 24 19 15 18 14 12
ZONAL LUMEN SUMMARY
ZONE LUMENS % BARE LAMP %LUMINAIRE
0-90
90-180
0-180
16458
14324
2134 13.0
87.0
100.0
11.5
77.0
88.5
Note: Shaded area indicates locations of emergency sections (emergency wiring
controls all lamps or optional battery pack controls one or two lamps).
*Note: Additional power mounts may be required for some runs with T5 HO
lamping options, longer runs, and runs with wiring options that are more complex.
Please consult factory for assistance.