Lightolier Baselyte-BSL4 Indoor Furnishings User Manual


 
Lighting Systems Baselyte-BSL4
Page 2 of 7 1 Light T5 HO Direct/Indirect
Lightolier a Genlyte Company www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2005 Genlyte Group LLC • 0205 Rev.1
Job Information Type:
Performance
Candlepower Curve Candlepower Summary Coefficients of Utilization
-ODULE,ENGTH
-OUNTING$ISTANCE
-ODULE,ENGTH-OUNTING$ISTANCE
-ODULE,ENGTH-OUNTING$ISTANCE
@
@
@
Module Lengths & Mounting Distances
Note: Shaded area indicates locations of emergency sections (emergency wiring
controls all lamps or optional battery pack controls one or two lamps).
Joiner
BSLESW = suspended standard white
End Set
BSLJS = suspended joiner
System Components & Accessories
Run Configuration
*Note: Additional power mounts may be required for some runs with T5 HO
lamping options, longer runs, and runs with wiring options that are more complex.
Please consult factory for assistance.
Report No: 2101633
Lamps: F54T5
Lumens per Lamp: 4650
Efficiency: 93.5%
Up: 98.5% Down: 1.5%
Run
Length
4’
Module
8’
Module
12’
Module
Joiner End Set Mount
Power
Mount*
4’ run 1 1 1 1
8’ run 1 1 1 1
12’ run
1 1 1 1
16’ run
2 1 1 2 1
20’ run 1 1 1 1 2 1
24’ run 2 1 1 2 1
28’ run 2 1 2 1 3 1
32’ run 1 2 2 1 3 1
Zonal Lumen Summary
ZONE LUMENS %BARE LAMP %LUMINAIRE






















CANDLEPOWER SUMMARY
ZONE CANDLEPOWER
DEG. 0 22.5 45 67.5 90
180 1047 1047 1047 1047 1047
175 1042 1042 1047 1049 1050
165 1002 1011 1034 1051 1058
155 930 951 1007 1051 1067
0
145 826 867 965 1043 1070
1
135 694 766 912 1025 1062
2
125 541 651 850 993 1038
3
115 375 535 777 925 978
4
105 203 421 640 693 707
5
95 55 137 99 35 34
6
90 3 6 8 8 7
7
85 5 5 6 7 6
8
75 7 6 7 8 8
9
65 6 10 10 10 10
10
55 7 11 16 12 12
45 8 9 17 23 23
35 9 9 13 19 21
25 9 10 10 13 13
15 9 10 11 11 11
5 9 9 10 10 10
0 9 9 9 9 9
COEFFICIENTS OF UTILIZATION
% EFFECTIVE CEILING CAVITY REFLECTANCE
80 70 50
% WALL REFLECTANCE
50 30 10 50 30 10 50 30 10
0 89 89 89 76 76 76 52 52 52
1 77 73 70 66 63 61 45 44 42
2 67 62 57 57 53 50 39 37 35
3 59 52 47 50 45 41 35 31 29
4 52 45 40 44 39 34 30 27 24
5 46 39 33 39 33 29 27 23 21
6 40 34 29 35 29 25 24 20 18
7 36 29 25 31 25 21 22 18 15
8 32 26 21 28 22 19 19 16 13
9 29 23 19 25 20 16 17 14 11
10 27 20 16 23 18 14 16 12 10
ZONAL LUMEN SUMMARY
ZONE LUMENS % BARE LAMP %LUMINAIRE
0-90
90-180
0-180
4351
4286
65 1.5
98.5
100.0
1.4
92.2
93.6
COEFFICIENTS OF UTILIZATION
% EFFECTIVE CEILING CAVITY REFLECTANCE
80 70 50
% WALL REFLECTANCE
50 30 10 50 30 10 50 30 10
0 89 89 89 76 76 76 52 52 52
1 77 73 70 66 63 61 45 44 42
2 67 62 57 57 53 50 39 37 35
3 59 52 47 50 45 41 35 31 29
4 52 45 40 44 39 34 30 27 24
5 46 39 33 39 33 29 27 23 21
6 40 34 29 35 29 25 24 20 18
7 36 29 25 31 25 21 22 18 15
8 32 26 21 28 22 19 19 16 13
9 29 23 19 25 20 16 17 14 11
10 27 20 16 23 18 14 16 12 10
ZONAL LUMEN SUMMARY
ZONE LUMENS % BARE LAMP %LUMINAIRE
0-90
90-180
0-180
4351
4286
65 1.5
98.5
100.0
1.4
92.2
93.6