Job Information Type:
Performance
Candlepower Curve Candlepower Summary Coefficients of Utilization
Report No: 2101687
Lamps: F32T8
Lumens per Lamp: 2950
Efficiency: 50.0%
Up: 100.0% Down: 0.0%
Zonal Lumen Summary
ZONE LUMENS %BARE LAMP %LUMINAIRE







































CANDLEPOWER SUMMARY
ZONE CANDLEPOWER
DEG. 0 45 90 135 180
180 309 309 309 309 309
175 327 322 308 293 288
165 354 340 299 257 242
155 414 349 279 216 196
145 510 389 250 174 155
135 606 440 215 134 115
125 714 492 173 98 93
115 764 532 126 71 74
105 480 466 70 49 48
95 168 166 18 17 19
90 14 15 1 5 6
85 0 0 0 0 0
75 0 0 0 0 0
65 0 0 0 0 0
55 0 0 0 0 0
45 0 0 0 0 0
35 0 0 0 0 0
25 0 0 0 0 0
15 0 0 0 0 0
5 0 0 0 0 0
0 0 0 0 0 0
COEFFICIENTS OF UTILIZATION
% EFFECTIVE CEILING CAVITY REFLECTANCE
80 70 50
% WALL REFLECTANCE
50 30 10 50 30 10 50 30 10
0 47 47 47 40 40 40 27 27 27
1 41 39 38 35 34 32 24 23 22
2 36 33 31 31 28 26 21 19 18
3 31 28 25 27 24 22 18 17 15
4 27 24 21 24 21 18 16 14 13
5 24 21 18 21 18 15 14 12 11
6 22 18 15 18 15 13 13 11 9
7 19 16 13 16 13 11 11 9 8
8 17 14 11 15 12 10 10 8 7
9 16 12 10 13 10 8 9 7 6
10 14 11 9 12 9 7 8 6 5
ZONAL LUMEN SUMMARY
ZONE LUMENS % BARE LAMP %LUMINAIRE
0-90
90-180
0-180
1475
1475
0 0
100.0
100.0
0
50.0
50.0
COEFFICIENTS OF UTILIZATION
% EFFECTIVE CEILING CAVITY REFLECTANCE
80 70 50
% WALL REFLECTANCE
50 30 10 50 30 10 50 30 10
0 47 47 47 40 40 40 27 27 27
1 41 39 38 35 34 32 24 23 22
2 36 33 31 31 28 26 21 19 18
3 31 28 25 27 24 22 18 17 15
4 27 24 21 24 21 18 16 14 13
5 24 21 18 21 18 15 14 12 11
6 22 18 15 18 15 13 13 11 9
7 19 16 13 16 13 11 11 9 8
8 17 14 11 15 12 10 10 8 7
9 16 12 10 13 10 8 9 7 6
10 14 11 9 12 9 7 8 6 5
ZONAL LUMEN SUMMARY
ZONE LUMENS % BARE LAMP %LUMINAIRE
0-90
90-180
0-180
1475
1475
0 0
100.0
100.0
0
50.0
50.0
Module Lengths & Mounting Distances
Run Configuration
Run
Length
4’
Module
8’
Module
12’
Module
Joiner End Set Mount
Power
Mount*
4’ run 1 1 1 1
8’ run 1 1 1 1
12’ run
1 1 1 1
16’ run
2 1 1 2 1
20’ run 1 1 1 1 2 1
24’ run 2 1 1 2 1
28’ run 2 1 2 1 3 1
32’ run 1 2 2 1 3 1
-ODULE,ENGTH
-OUNTING$ISTANCE
-ODULE,ENGTH-OUNTING$ISTANCE
-ODULE,ENGTH-OUNTING$ISTANCE
@
@
@
Joiner
BSLEWW = wall mount standard white
Dust Cover
End Set
BSLJW = wall mount joiner
BSLDCW = 4’ wall mount dust cover
System Components & Accessories
Non-Power Wall Mount Power Wall Mount
BSLWP1 = 1-power mount
BSLWP2 = 2-power mount
BSLWN = non-power wall mount
Note: Shaded area indicates locations of emergency sections (emergency wiring
controls all lamps or optional battery pack controls one or two lamps).
*Note: Additional power mounts may be required for some runs with T5 HO
lamping options, longer runs, and runs with wiring options that are more complex.
Please consult factory for assistance.