Lightolier Baselyte-BSL26 Indoor Furnishings User Manual


 
Lighting Systems Baselyte-BSL26
Page 2 of 8 2 Light T5 HO Indirect
Lightolier a Genlyte Company www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2005 Genlyte Group LLC • 0205 Rev.1
Job Information Type:
Performance
Candlepower Curve Candlepower Summary Coefficients of Utilization
Module Lengths & Mounting Distances
Joiner
BSLESW = suspended standard white
End Set
BSLJS = suspended joiner
System Components & Accessories
Run Configuration
Run
Length
4’
Module
8’
Module
12’
Module
Joiner End Set Mount
Power
Mount*
4’ run 1 1 1 1
8’ run 1 1 1 1
12’ run
1 1 1 1
16’ run
2 1 1 2 1
20’ run 1 1 1 1 2 1
24’ run 2 1 1 2 1
28’ run 2 1 2 1 3 1
32’ run 1 2 2 1 3 1
Report No: 2101711
Lamps: F54T5
Lumens per Lamp: 4650
Efficiency: 96.9%
Up: 100.0% Down: 0.0%
Zonal Lumen Summary
ZONE LUMENS %BARE LAMP %LUMINAIRE
-ODULE,ENGTH
-OUNTING$ISTANCE
-ODULE,ENGTH-OUNTING$ISTANCE
-ODULE,ENGTH-OUNTING$ISTANCE
@
@
@






















CANDLEPOWER SUMMARY
ZONE CANDLEPOWER
DEG. 0 22.5 45 67.5 90
180 2352 2352 2352 2352 2352
175 2339 2344 2352 2359 2363
165 2252 2281 2324 2362 2376
155 2092 2153 2252 2343 2374
145 1862 1966 2143 2269 2305
135 1572 1730 1970 2121 2163
125 1234 1460 1729 1899 1957
115 858 1119 1448 1621 1661
105 475 770 1082 1119 1139
95 113 267 458 389 406
90 5 4 13 6 8
85 0 0 0 0 0
75 0 0 0 0 0
65 0 0 0 0 0
55 0 0 0 0 0
45 0 0 0 0 0
35 0 0 0 0 0
25 0 0 0 0 0
15 0 0 0 0 0
5 0 0 0 0 0
0 0 0 0 0 0
COEFFICIENTS OF UTILIZATION
% EFFECTIVE CEILING CAVITY REFLECTANCE
80 70 50
% WALL REFLECTANCE
50 30 10 50 30 10 50 30 10
0 91 91 91 78 78 78 53 53 53
1 79 76 73 68 65 62 46 44 43
2 69 64 59 59 55 51 40 38 35
3 60 54 49 52 46 42 35 32 30
4 53 46 41 45 40 35 31 28 25
5 47 40 35 40 34 30 28 24 21
6 42 35 29 36 30 26 25 21 18
7 37 30 25 32 26 22 22 18 15
8 34 27 22 29 23 19 20 16 13
9 30 24 19 26 20 17 18 14 12
10 27 21 17 24 18 15 16 13 10
ZONAL LUMEN SUMMARY
ZONE LUMENS % BARE LAMP %LUMINAIRE
0-90
90-180
0-180
8923
8923
0 0
100.0
100.0
0
95.9
95.9
COEFFICIENTS OF UTILIZATION
% EFFECTIVE CEILING CAVITY REFLECTANCE
80 70 50
% WALL REFLECTANCE
50 30 10 50 30 10 50 30 10
0 91 91 91 78 78 78 53 53 53
1 79 76 73 68 65 62 46 44 43
2 69 64 59 59 55 51 40 38 35
3 60 54 49 52 46 42 35 32 30
4 53 46 41 45 40 35 31 28 25
5 47 40 35 40 34 30 28 24 21
6 42 35 29 36 30 26 25 21 18
7 37 30 25 32 26 22 22 18 15
8 34 27 22 29 23 19 20 16 13
9 30 24 19 26 20 17 18 14 12
10 27 21 17 24 18 15 16 13 10
ZONAL LUMEN SUMMARY
ZONE LUMENS % BARE LAMP %LUMINAIRE
0-90
90-180
0-180
8923
8923
0 0
100.0
100.0
0
95.9
95.9
*Note: Additional power mounts may be required for some runs with T5 HO
lamping options, longer runs, and runs with wiring options that are more complex.
Please consult factory for assistance.
Note: Shaded area indicates locations of emergency sections (emergency wiring
controls all lamps or optional battery pack controls one or two lamps).