Lightolier Baselyte-BSL25 Indoor Furnishings User Manual


 
Lighting Systems Baselyte-BSL25
Page 2 of 7 1 Light T5 HO Indirect
Lightolier a Genlyte Company www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2005 Genlyte Group LLC • 0205 Rev.1
Job Information Type:
Performance
Candlepower Curve Candlepower Summary Coefficients of Utilization
Module Lengths & Mounting Distances
Joiner
BSLESW = suspended standard white
End Set
BSLJS = suspended joiner
System Components & Accessories
Run Configuration
Run
Length
4’
Module
8’
Module
12’
Module
Joiner End Set Mount
Power
Mount*
4’ run 1 1 1 1
8’ run 1 1 1 1
12’ run
1 1 1 1
16’ run
2 1 1 2 1
20’ run 1 1 1 1 2 1
24’ run 2 1 1 2 1
28’ run 2 1 2 1 3 1
32’ run 1 2 2 1 3 1
Report No: 2101709
Lamps: F54T5
Lumens per Lamp: 4650
Efficiency: 94.9%
Up: 100.0% Down: 0.0%
Zonal Lumen Summary
ZONE LUMENS %BARE LAMP %LUMINAIRE
-ODULE,ENGTH
-OUNTING$ISTANCE
-ODULE,ENGTH-OUNTING$ISTANCE
-ODULE,ENGTH-OUNTING$ISTANCE
@
@
@






















CANDLEPOWER SUMMARY
ZONE CANDLEPOWER
DEG. 0 22.5 45 67.5 90
180 1078 1078 1078 1078 1078
175 1073 1073 1077 1080 1081
165 1035 1042 1064 1079 1086
155 963 980 1032 1073 1090
145 860 892 985 1057 1083
135 721 786 925 1031 1070
125 564 667 857 998 1051
115 385 546 792 946 1001
105 197 435 647 691 754
95 35 165 156 80 109
90 2 3 7 3 7
85 0 0 0 0 0
75 0 0 0 0 0
65 0 0 0 0 0
55 0 0 0 0 0
45 0 0 0 0 0
35 0 0 0 0 0
25 0 0 0 0 0
15 0 0 0 0 0
5 0 0 0 0 0
0 0 0 0 0 0
COEFFICIENTS OF UTILIZATION
% EFFECTIVE CEILING CAVITY REFLECTANCE
80 70 50
% WALL REFLECTANCE
50 30 10 50 30 10 50 30 10
0 90 90 90 77 77 77 52 52 52
1 78 74 71 66 64 61 45 44 42
2 68 62 58 58 54 50 40 37 35
3 59 53 48 51 46 42 35 32 29
4 52 45 40 45 39 35 31 27 24
5 46 39 34 40 34 29 27 23 21
6 41 34 29 35 29 25 24 20 18
7 37 30 25 31 26 22 22 18 15
8 33 26 22 28 23 19 19 16 13
9 30 23 19 26 20 16 18 14 11
10 27 21 17 23 18 14 16 12 10
ZONAL LUMEN SUMMARY
ZONE LUMENS % BARE LAMP %LUMINAIRE
0-90
90-180
0-180
4413
4413
0 0
100.0
100.0
0
94.9
94.9
COEFFICIENTS OF UTILIZATION
% EFFECTIVE CEILING CAVITY REFLECTANCE
80 70 50
% WALL REFLECTANCE
50 30 10 50 30 10 50 30 10
0 90 90 90 77 77 77 52 52 52
1 78 74 71 66 64 61 45 44 42
2 68 62 58 58 54 50 40 37 35
3 59 53 48 51 46 42 35 32 29
4 52 45 40 45 39 35 31 27 24
5 46 39 34 40 34 29 27 23 21
6 41 34 29 35 29 25 24 20 18
7 37 30 25 31 26 22 22 18 15
8 33 26 22 28 23 19 19 16 13
9 30 23 19 26 20 16 18 14 11
10 27 21 17 23 18 14 16 12 10
ZONAL LUMEN SUMMARY
ZONE LUMENS % BARE LAMP %LUMINAIRE
0-90
90-180
0-180
4413
4413
0 0
100.0
100.0
0
94.9
94.9
Note: Shaded area indicates locations of emergency sections (emergency wiring
controls all lamps or optional battery pack controls one or two lamps).
*Note: Additional power mounts may be required for some runs with T5 HO
lamping options, longer runs, and runs with wiring options that are more complex.
Please consult factory for assistance.