Lightolier Baselyte-BSL22 Indoor Furnishings User Manual


 
Lighting Systems Baselyte-BSL22
Page 2 of 8 2 Light T8 Indirect
Lightolier a Genlyte Company www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2005 Genlyte Group LLC • 0205 Rev.1
Job Information Type:
Performance
Candlepower Curve Candlepower Summary Coefficients of Utilization
Module Lengths & Mounting Distances
Joiner
BSLESW = suspended standard white
Dust CoverEnd Set
BSLJS = suspended joiner
BSLDCS = 4’ suspended dust cover
System Components & Accessories
Run Configuration
Run
Length
4’
Module
8’
Module
12’
Module
Joiner End Set Mount
Power
Mount*
4’ run 1 1 1 1
8’ run 1 1 1 1
12’ run
1 1 1 1
16’ run
2 1 1 2 1
20’ run 1 1 1 1 2 1
24’ run 2 1 1 2 1
28’ run 2 1 2 1 3 1
32’ run 1 2 2 1 3 1
Report No: 2101584
Lamps: F32T8
Lumens per Lamp: 2950
Efficiency: 87.7.%
Up: 100.0% Down: 0.0%
Zonal Lumen Summary
ZONE LUMENS %BARE LAMP %LUMINAIRE
-ODULE,ENGTH
-OUNTING$ISTANCE
-ODULE,ENGTH-OUNTING$ISTANCE
-ODULE,ENGTH-OUNTING$ISTANCE
@
@
@






















CANDLEPOWER SUMMARY
ZONE CANDLEPOWER
DEG. 0 22.5 45 67.5 90
180 1339 1339 1339 1339 1339
175 1332 1335 1339 1342 1343
165 1285 1297 1323 1342 1350
155 1196 1222 1287 1337 1358
145 1069 1115 1233 1323 1358
135 906 985 1164 1293 1339
125 713 839 1081 1209 1253
115 495 695 931 985 1007
105 266 490 600 558 565
95 68 114 166 131 136
90 2 2 10 4 6
85 0 0 0 0 0
75 0 0 0 0 0
65 0 0 0 0 0
55 0 0 0 0 0
45 0 0 0 0 0
35 0 0 0 0 0
25 0 0 0 0 0
15 0 0 0 0 0
5 0 0 0 0 0
0 0 0 0 0 0
COEFFICIENTS OF UTILIZATION
% EFFECTIVE CEILING CAVITY REFLECTANCE
80 70 50
% WALL REFLECTANCE
50 30 10 50 30 10 50 30 10
0 83 83 83 71 71 71 48 48 48
1 72 69 66 62 59 57 42 41 39
2 63 58 54 54 50 46 37 34 32
3 55 49 45 47 42 39 32 29 27
4 48 42 37 41 36 32 28 25 23
5 43 36 31 37 31 27 25 22 19
6 38 32 27 33 27 23 22 19 16
7 34 28 23 29 24 20 20 17 14
8 31 24 20 26 21 17 18 15 12
9 28 22 17 24 19 15 16 13 11
10 25 19 15 21 17 13 15 12 9
ZONAL LUMEN SUMMARY
ZONE LUMENS % BARE LAMP %LUMINAIRE
0-90
90-180
0-180
5178
5178
0 0
100.0
100.0
0
87.8
87.8
COEFFICIENTS OF UTILIZATION
% EFFECTIVE CEILING CAVITY REFLECTANCE
80 70 50
% WALL REFLECTANCE
50 30 10 50 30 10 50 30 10
0 83 83 83 71 71 71 48 48 48
1 72 69 66 62 59 57 42 41 39
2 63 58 54 54 50 46 37 34 32
3 55 49 45 47 42 39 32 29 27
4 48 42 37 41 36 32 28 25 23
5 43 36 31 37 31 27 25 22 19
6 38 32 27 33 27 23 22 19 16
7 34 28 23 29 24 20 20 17 14
8 31 24 20 26 21 17 18 15 12
9 28 22 17 24 19 15 16 13 11
10 25 19 15 21 17 13 15 12 9
ZONAL LUMEN SUMMARY
ZONE LUMENS % BARE LAMP %LUMINAIRE
0-90
90-180
0-180
5178
5178
0 0
100.0
100.0
0
87.8
87.8
Note: Shaded area indicates locations of emergency sections (emergency wiring
controls all lamps or optional battery pack controls one or two lamps).
*Note: Additional power mounts may be required for some runs with T5 HO
lamping options, longer runs, and runs with wiring options that are more complex.
Please consult factory for assistance.