Page 2 of 8 3 Light T8 Direct/Indirect
Lightolier a Genlyte Company www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2005 Genlyte Group LLC • 0205 Rev.1
Job Information Type:
Performance
Candlepower Curve Candlepower Summary Coefficients of Utilization
-ODULE,ENGTH
-OUNTING$ISTANCE
-ODULE,ENGTH-OUNTING$ISTANCE
-ODULE,ENGTH-OUNTING$ISTANCE
@
@
@
Module Lengths & Mounting Distances
Note: Shaded area indicates locations of emergency sections (emergency wiring
controls all lamps or optional battery pack controls one or two lamps).
Joiner
BSLESW = suspended standard white
Dust CoverEnd Set
BSLJS = suspended joiner
BSLDCS = 4’ suspended dust cover
System Components & Accessories
Run Configuration
*Note: Additional power mounts may be required for some runs with T5 HO
lamping options, longer runs, and runs with wiring options that are more complex.
Please consult factory for assistance.






















Report No: 2101590
Lamps: F32T8
Lumens per Lamp: 2950
Efficiency: 84.1%
Up: 82.2% Down: 17.8%
CANDLEPOWER SUMMARY
ZONE CANDLEPOWER
DEG. 0 22.5 45 67.5 90
180 1740 1740 1740 1740 1740
175 1730 1730 1733 1729 1730
165 1668 1665 1681 1689 1696
155 1554 1555 1597 1616 1631
145 1389 1402 1479 1551 1582
135 1179 1208 1357 1469 1511
125 927 998 1208 1339 1377
115 647 777 1002 1058 1096
105 353 525 655 647 676
95 91 147 213 186 212
90 7 29 45 53 51
85 23 35 53 58 62
75 52 62 98 96 102
65 98 117 128 152 169
55 201 191 194 186 195
45 329 282 260 256 262
35 452 391 339 316 322
25 568 508 472 418 412
15 663 626 592 558 562
5 720 712 701 681 685
0 727 727 727 727 727
COEFFICIENTS OF UTILIZATION
% EFFECTIVE CEILING CAVITY REFLECTANCE
80 70 50
% WALL REFLECTANCE
50 30 10 50 30 10 50 30 10
0 83 83 83 73 73 73 55 55 55
1 72 69 66 64 61 59 48 46 44
2 63 58 54 56 52 48 42 39 37
3 55 50 45 49 44 40 37 34 31
4 49 43 38 43 38 34 33 29 26
5 43 37 32 38 33 29 29 25 22
6 39 32 28 34 29 25 26 22 19
7 35 29 24 31 26 22 24 20 17
8 31 25 21 28 23 19 21 18 15
9 29 23 19 25 20 17 19 16 13
10 26 20 17 23 18 15 18 14 12
ZONAL LUMEN SUMMARY
ZONE LUMENS % BARE LAMP %LUMINAIRE
0-90
90-180
0-180
7447
6118.5
1328.5 17.8
82.2
100.0
15.0
69.1
84.1
COEFFICIENTS OF UTILIZATION
% EFFECTIVE CEILING CAVITY REFLECTANCE
80 70 50
% WALL REFLECTANCE
50 30 10 50 30 10 50 30 10
0 83 83 83 73 73 73 55 55 55
1 72 69 66 64 61 59 48 46 44
2 63 58 54 56 52 48 42 39 37
3 55 50 45 49 44 40 37 34 31
4 49 43 38 43 38 34 33 29 26
5 43 37 32 38 33 29 29 25 22
6 39 32 28 34 29 25 26 22 19
7 35 29 24 31 26 22 24 20 17
8 31 25 21 28 23 19 21 18 15
9 29 23 19 25 20 17 19 16 13
10 26 20 17 23 18 15 18 14 12
ZONAL LUMEN SUMMARY
ZONE LUMENS % BARE LAMP %LUMINAIRE
0-90
90-180
0-180
7447
6118.5
1328.5 17.8
82.2
100.0
15.0
69.1
84.1
Run
Length
4’
Module
8’
Module
12’
Module
Joiner End Set Mount
Power
Mount*
4’ run 1 1 1 1
8’ run 1 1 1 1
12’ run 1 1 1 1
16’ run 2 1 1 2 1
20’ run 1 1 1 1 2 1
24’ run 2 1 1 2 1
28’ run 2 1 2 1 3 1
32’ run 1 2 2 1 3 1
Zonal Lumen Summary
ZONE LUMENS %BARE LAMP %LUMINAIRE