Lightolier Baselyte-BSL17 Indoor Furnishings User Manual


 
Lighting Systems Baselyte-BSL17
Page 2 of 8 4 Light T5 HO Semi-Indirect
Lightolier a Genlyte Company www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2005 Genlyte Group LLC • 0205 Rev.1
Job Information Type:
Performance
Candlepower Curve Candlepower Summary Coefficients of Utilization
Module Lengths & Mounting Distances
Joiner
BSLESW = suspended standard white
End Set
BSLJS = suspended joiner
System Components & Accessories
Run Configuration
Run
Length
4’
Module
8’
Module
12’
Module
Joiner End Set Mount
Power
Mount*
4’ run 1 1 1 1
8’ run 1 1 1 1
12’ run
1 1 1 1
16’ run
2 1 1 2 1
20’ run 1 1 1 1 2 1
24’ run 2 1 1 2 1
28’ run 2 1 2 1 3 1
32’ run 1 2 2 1 3 1
Report No: 9900158
Lamps: F54T5
Lumens per Lamp: 4650
Efficiency: 87.6%
Up: 96.5% Down: 3.5%
-ODULE,ENGTH
-OUNTING$ISTANCE
-ODULE,ENGTH-OUNTING$ISTANCE
-ODULE,ENGTH-OUNTING$ISTANCE
@
@
@
Zonal Lumen Summary
ZONE LUMENS %BARE LAMP %LUMINAIRE






















Candle
p
ower Summar
y
ZONE CANDLEPOWER
DEG. 0 22.5 45 67.5 90
180 4535 4535 4535 4535 4535
175 4511 4513 4528 4538 4542
165 4347 4377 4448 4493 4508
155 4041 4109 4228 4313 4351
145 3601 3708 3907 4090 4165
135 3046 3188 3531 3842 3957
125 2389 2602 3123 3461 3575
115 1672 2004 2541 2699 2756
105 906 1310 1574 1575 1608
95 171 325 395 318 334
90 6 16 37 55 64
85 16 22 41 62 70
75 26 35 61 85 94
65 33 53 84 107 116
55 50 75 102 127 136
45 76 94 118 137 145
35 105 114 134 148 155
25 129 134 148 156 160
15 145 147 153 161 163
5 155 154 155 156 155
0 156 156 156 156 156
COEFFICIENTS OF UTILIZATION
% EFFECTIVE CEILING CAVITY REFLECTANCE
80 70 50
% WALL REFLECTANCE
50 30 10 50 30 10 50 30 10
0 84 84 84 72 72 72 50 50 50
1 73 69 66 62 60 57 43 42 40
2 63 58 54 54 50 47 38 35 33
3 55 49 45 48 43 39 33 30 28
4 49 42 37 42 37 33 29 26 23
5 43 36 32 37 32 28 26 22 20
6 38 32 27 33 27 24 23 19 17
7 34 28 23 29 24 20 21 17 14
8 31 24 20 26 21 18 19 15 13
9 28 22 18 24 19 15 17 13 11
10 25 19 15 22 17 13 15 12 10
ZONAL LUMEN SUMMARY
ZONE LUMENS % BARE LAMP %LUMINAIRE
0-90
90-180
0-180
16301
15725
576 3.5
96.5
100.0
3.1
84.5
87.6
COEFFICIENTS OF UTILIZATION
% EFFECTIVE CEILING CAVITY REFLECTANCE
80 70 50
% WALL REFLECTANCE
50 30 10 50 30 10 50 30 10
0 84 84 84 72 72 72 50 50 50
1 73 69 66 62 60 57 43 42 40
2 63 58 54 54 50 47 38 35 33
3 55 49 45 48 43 39 33 30 28
4 49 42 37 42 37 33 29 26 23
5 43 36 32 37 32 28 26 22 20
6 38 32 27 33 27 24 23 19 17
7 34 28 23 29 24 20 21 17 14
8 31 24 20 26 21 18 19 15 13
9 28 22 18 24 19 15 17 13 11
10 25 19 15 22 17 13 15 12 10
ZONAL LUMEN SUMMARY
ZONE LUMENS % BARE LAMP %LUMINAIRE
0-90
90-180
0-180
16301
15725
576 3.5
96.5
100.0
3.1
84.5
87.6
Note: Shaded area indicates locations of emergency sections (emergency wiring
controls all lamps or optional battery pack controls one or two lamps).
*Note: Additional power mounts may be required for some runs with T5 HO
lamping options, longer runs, and runs with wiring options that are more complex.
Please consult factory for assistance.