Lightolier Baselyte-BSL16 Indoor Furnishings User Manual


 
Lighting Systems Baselyte-BSL16
Page 2 of 8 3 Light T5 HO Semi-Indirect
Lightolier a Genlyte Company www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2005 Genlyte Group LLC • 0205 Rev.1
Job Information Type:
Performance
Candlepower Curve Candlepower Summary Coefficients of Utilization
Module Lengths & Mounting Distances
Joiner
BSLESW = suspended standard white
End Set
BSLJS = suspended joiner
System Components & Accessories
Run Configuration
Run
Length
4’
Module
8’
Module
12’
Module
Joiner End Set Mount
Power
Mount*
4’ run 1 1 1 1
8’ run 1 1 1 1
12’ run
1 1 1 1
16’ run
2 1 1 2 1
20’ run 1 1 1 1 2 1
24’ run 2 1 1 2 1
28’ run 2 1 2 1 3 1
32’ run 1 2 2 1 3 1
Report No: 9900159
Lamps: F54T5
Lumens per Lamp: 4650
Efficiency: 84.9%
Up: 96.1% Down: 3.9%
-ODULE,ENGTH
-OUNTING$ISTANCE
-ODULE,ENGTH-OUNTING$ISTANCE
-ODULE,ENGTH-OUNTING$ISTANCE
@
@
@
Zonal Lumen Summary
ZONE LUMENS %BARE LAMP %LUMINAIRE






















Candle
p
ower Summar
y
ZONE CANDLEPOWER
DEG. 0 22.5 45 67.5 90
180 3199 3199 3199 3199 3199
175 3184 3183 3190 3201 3204
165 3072 3089 3135 3155 3165
155 2858 2901 2961 3016 3042
145 2551 2605 2731 2843 2889
135 2165 2236 2450 2663 2747
125 1714 1818 2174 2470 2571
115 1214 1390 1865 2056 2128
105 657 975 1266 1342 1404
95 154 302 387 341 367
90 5 13 30 46 55
85 11 16 31 49 56
75 19 25 47 67 75
65 26 40 65 84 92
55 41 58 81 99 107
45 64 75 94 111 118
35 88 92 109 119 125
25 109 110 120 127 131
15 123 123 126 131 133
5 131 131 131 131 131
0 132 132 132 132 132
COEFFICIENTS OF UTILIZATION
% EFFECTIVE CEILING CAVITY REFLECTANCE
80 70 50
% WALL REFLECTANCE
50 30 10 50 30 10 50 30 10
0 81 81 81 70 70 70 49 49 49
1 70 67 64 60 58 56 42 41 39
2 61 56 52 53 49 45 37 34 32
3 54 48 43 46 41 38 32 29 27
4 47 41 36 41 36 32 28 25 23
5 42 35 31 36 31 27 25 22 19
6 37 31 26 32 27 23 22 19 16
7 33 27 22 29 23 20 20 17 14
8 30 24 19 26 21 17 18 15 12
9 27 21 17 23 18 15 16 13 11
10 24 19 15 21 16 13 15 12 9
ZONAL LUMEN SUMMARY
ZONE LUMENS % BARE LAMP %LUMINAIRE
0-90
90-180
0-180
11841
11380
461 3.9
96.1
100.0
3.3
81.6
84.9
COEFFICIENTS OF UTILIZATION
% EFFECTIVE CEILING CAVITY REFLECTANCE
80 70 50
% WALL REFLECTANCE
50 30 10 50 30 10 50 30 10
0 81 81 81 70 70 70 49 49 49
1 70 67 64 60 58 56 42 41 39
2 61 56 52 53 49 45 37 34 32
3 54 48 43 46 41 38 32 29 27
4 47 41 36 41 36 32 28 25 23
5 42 35 31 36 31 27 25 22 19
6 37 31 26 32 27 23 22 19 16
7 33 27 22 29 23 20 20 17 14
8 30 24 19 26 21 17 18 15 12
9 27 21 17 23 18 15 16 13 11
10 24 19 15 21 16 13 15 12 9
ZONAL LUMEN SUMMARY
ZONE LUMENS % BARE LAMP %LUMINAIRE
0-90
90-180
0-180
11841
11380
461 3.9
96.1
100.0
3.3
81.6
84.9
Note: Shaded area indicates locations of emergency sections (emergency wiring
controls all lamps or optional battery pack controls one or two lamps).
*Note: Additional power mounts may be required for some runs with T5 HO
lamping options, longer runs, and runs with wiring options that are more complex.
Please consult factory for assistance.