Lightolier Baselyte-BSL15 Indoor Furnishings User Manual


 
Lighting Systems Baselyte-BSL15
Page 2 of 8 2 Light T5 HO Semi-Indirect
Lightolier a Genlyte Company www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2005 Genlyte Group LLC • 0205 Rev.1
Job Information Type:
Performance
Candlepower Curve Candlepower Summary Coefficients of Utilization
Module Lengths & Mounting Distances
Joiner
BSLESW = suspended standard white
End Set
BSLJS = suspended joiner
System Components & Accessories
Run Configuration
Run
Length
4’
Module
8’
Module
12’
Module
Joiner End Set Mount
Power
Mount*
4’ run 1 1 1 1
8’ run 1 1 1 1
12’ run
1 1 1 1
16’ run
2 1 1 2 1
20’ run 1 1 1 1 2 1
24’ run 2 1 1 2 1
28’ run 2 1 2 1 3 1
32’ run 1 2 2 1 3 1
Report No: 9900160
Lamps: F54T5
Lumens per Lamp: 4650
Efficiency: 80.8%
Up: 94.7% Down: 5.3%
-ODULE,ENGTH
-OUNTING$ISTANCE
-ODULE,ENGTH-OUNTING$ISTANCE
-ODULE,ENGTH-OUNTING$ISTANCE
@
@
@
Zonal Lumen Summary
ZONE LUMENS %BARE LAMP %LUMINAIRE






















Candle
p
ower Summar
y
ZONE CANDLEPOWER
DEG. 0 22.5 45 67.5 90
180 2038 2038 2038 2038 2038
175 2026 2027 2031 2036 2039
165 1952 1964 1977 1988 1994
155 1813 1832 1862 1887 1899
145 1613 1641 1697 1749 1771
135 1367 1403 1496 1611 1660
125 1077 1125 1307 1494 1556
115 751 837 1126 1263 1300
105 398 591 816 878 906
95 74 217 341 316 330
90 3 11 25 40 49
85 7 12 27 43 49
75 14 20 40 59 66
65 21 33 55 73 81
55 35 49 70 86 94
45 56 65 82 96 103
35 78 82 95 105 110
25 97 98 105 111 115
15 110 111 113 116 118
5 118 118 118 118 118
0 119 119 119 119 119
COEFFICIENTS OF UTILIZATION
% EFFECTIVE CEILING CAVITY REFLECTANCE
80 70 50
% WALL REFLECTANCE
50 30 10 50 30 10 50 30 10
0 78 78 78 67 67 67 47 47 47
1 67 64 62 58 56 53 41 39 38
2 59 54 50 50 47 44 35 33 31
3 51 46 41 44 40 36 31 28 26
4 45 39 35 39 34 30 27 24 22
5 40 34 29 34 29 26 24 21 18
6 35 29 25 31 26 22 22 18 16
7 32 26 21 27 22 19 19 16 14
8 28 23 19 25 20 16 17 14 12
9 26 20 16 22 18 14 16 13 10
10 23 18 14 20 16 13 14 11 9
ZONAL LUMEN SUMMARY
ZONE LUMENS % BARE LAMP %LUMINAIRE
0-90
90-180
0-180
7516
7118.5
397.5 5.3
94.7
100.0
4.3
76.5
80.8
COEFFICIENTS OF UTILIZATION
% EFFECTIVE CEILING CAVITY REFLECTANCE
80 70 50
% WALL REFLECTANCE
50 30 10 50 30 10 50 30 10
0 78 78 78 67 67 67 47 47 47
1 67 64 62 58 56 53 41 39 38
2 59 54 50 50 47 44 35 33 31
3 51 46 41 44 40 36 31 28 26
4 45 39 35 39 34 30 27 24 22
5 40 34 29 34 29 26 24 21 18
6 35 29 25 31 26 22 22 18 16
7 32 26 21 27 22 19 19 16 14
8 28 23 19 25 20 16 17 14 12
9 26 20 16 22 18 14 16 13 10
10 23 18 14 20 16 13 14 11 9
ZONAL LUMEN SUMMARY
ZONE LUMENS % BARE LAMP %LUMINAIRE
0-90
90-180
0-180
7516
7118.5
397.5 5.3
94.7
100.0
4.3
76.5
80.8
*Note: Additional power mounts may be required for some runs with T5 HO
lamping options, longer runs, and runs with wiring options that are more complex.
Please consult factory for assistance.
Note: Shaded area indicates locations of emergency sections (emergency wiring