Lightolier Baselyte-BSL14 Indoor Furnishings User Manual


 
Lighting Systems Baselyte-BSL14
Page 2 of 7 1 Light T5 HO Semi-Indirect
Lightolier a Genlyte Company www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2005 Genlyte Group LLC • 0205 Rev.1
Job Information Type:
Performance
Candlepower Curve Candlepower Summary Coefficients of Utilization
Module Lengths & Mounting Distances
Joiner
BSLESW = suspended standard white
End Set
BSLJS = suspended joiner
System Components & Accessories
Run Configuration
Run
Length
4’
Module
8’
Module
12’
Module
Joiner End Set Mount
Power
Mount*
4’ run 1 1 1 1
8’ run 1 1 1 1
12’ run
1 1 1 1
16’ run
2 1 1 2 1
20’ run 1 1 1 1 2 1
24’ run 2 1 1 2 1
28’ run 2 1 2 1 3 1
32’ run 1 2 2 1 3 1
Report No: 9900245
Lamps: F54T54
Lumens per Lamp: 4650
Efficiency: 92.9%
Up: 98.8% Down: 1.2%
-ODULE,ENGTH
-OUNTING$ISTANCE
-ODULE,ENGTH-OUNTING$ISTANCE
-ODULE,ENGTH-OUNTING$ISTANCE
@
@
@
Zonal Lumen Summary
ZONE LUMENS %BARE LAMP %LUMINAIRE
Candle
p
ower Summar
y
ZONE CANDLEPOWER
DEG. 0 22.5 45 67.5 90
180 1073 1073 1073 1073 1073
175 1067 1069 1072 1074 1075
165 1027 1036 1054 1069 1074
155 954 974 1016 1053 1066
145 848 885 960 1028 1051
135 713 774 894 1005 1042
125 553 648 844 1042 1084
115 380 533 826 881 922
105 198 457 583 628 661
95 43 126 67 27 28
90 2 3 5 6 7
85 4 4 5 6 6
75 5 6 6 7 7
65 5 7 9 10 10
55 6 8 10 12 12
45 8 9 11 12 13
35 10 10 13 13 13
25 11 12 13 14 14
15 12 12 13 14 14
5 12 12 12 13 12
0 12 12 12 12 12
COEFFICIENTS OF UTILIZATION
% EFFECTIVE CEILING CAVITY REFLECTANCE
80 70 50
% WALL REFLECTANCE
50 30 10 50 30 10 50 30 10
0 88 88 88 75 75 75 52 52 52
1 76 73 70 65 63 60 45 43 42
2 66 61 57 57 53 49 39 37 34
3 58 52 47 50 45 41 34 31 29
4 51 44 39 44 38 34 30 27 24
5 45 38 33 39 33 29 27 23 20
6 40 33 28 34 29 25 24 20 17
7 36 29 24 31 25 21 21 18 15
8 32 26 21 28 22 18 19 16 13
9 29 23 18 25 20 16 17 14 11
10 26 20 16 23 18 14 16 12 10
ZONAL LUMEN SUMMARY
ZONE LUMENS % BARE LAMP %LUMINAIRE
0-90
90-180
0-180
4321
4267.5
53.5 1.2
98.8
100.0
1.2
91.8
92.9
COEFFICIENTS OF UTILIZATION
% EFFECTIVE CEILING CAVITY REFLECTANCE
80 70 50
% WALL REFLECTANCE
50 30 10 50 30 10 50 30 10
0 88 88 88 75 75 75 52 52 52
1 76 73 70 65 63 60 45 43 42
2 66 61 57 57 53 49 39 37 34
3 58 52 47 50 45 41 34 31 29
4 51 44 39 44 38 34 30 27 24
5 45 38 33 39 33 29 27 23 20
6 40 33 28 34 29 25 24 20 17
7 36 29 24 31 25 21 21 18 15
8 32 26 21 28 22 18 19 16 13
9 29 23 18 25 20 16 17 14 11
10 26 20 16 23 18 14 16 12 10
ZONAL LUMEN SUMMARY
ZONE LUMENS % BARE LAMP %LUMINAIRE
0-90
90-180
0-180
4321
4267.5
53.5 1.2
98.8
100.0
1.2
91.8
92.9






















Note: Shaded area indicates locations of emergency sections (emergency wiring
controls all lamps or optional battery pack controls one or two lamps).
*Note: Additional power mounts may be required for some runs with T5 HO
lamping options, longer runs, and runs with wiring options that are more complex.
Please consult factory for assistance.