Lightolier Baselyte-BSL11 Indoor Furnishings User Manual


 
Lighting Systems Baselyte-BSL11
Page 2 of 8 2 Light T8 Semi-Indirect
Lightolier a Genlyte Company www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2005 Genlyte Group LLC • 0205 Rev.1
Job Information Type:
Performance
Candlepower Curve Candlepower Summary Coefficients of Utilization
Module Lengths & Mounting Distances
Joiner
BSLESW = suspended standard white
Dust Cover End Set
BSLJS = suspended joiner
BSLDCS = 4’ suspended dust cover
System Components & Accessories
Run Configuration
Run
Length
4’
Module
8’
Module
12’
Module
Joiner End Set Mount
Power
Mount*
4’ run 1 1 1 1
8’ run 1 1 1 1
12’ run
1 1 1 1
16’ run
2 1 1 2 1
20’ run 1 1 1 1 2 1
24’ run 2 1 1 2 1
28’ run 2 1 2 1 3 1
32’ run 1 2 2 1 3 1
Report No: 9900151
Lamps: F32T8
Lumens per Lamp: 2950
Efficiency: 80.0%
Up: 94.3% Down: 5.7%
-ODULE,ENGTH
-OUNTING$ISTANCE
-ODULE,ENGTH-OUNTING$ISTANCE
-ODULE,ENGTH-OUNTING$ISTANCE
@
@
@
Zonal Lumen Summary
ZONE LUMENS %BARE LAMP %LUMINAIRE






















Candle
p
ower Summar
y
ZONE CANDLEPOWER
DEG. 0 22.5 45 67.5 90
180 1268 1268 1268 1268 1268
175 1262 1261 1258 1255 1255
165 1218 1210 1217 1224 1226
155 1135 1130 1151 1166 1171
145 1017 1018 1052 1083 1095
135 863 873 933 993 1018
125 681 707 810 914 943
115 484 531 691 777 802
105 271 371 517 578 601
95 58 153 204 197 211
90 3 11 22 31 34
85 6 9 17 26 30
75 11 14 27 37 42
65 15 24 37 48 53
55 25 34 48 58 62
45 39 45 57 65 69
35 54 56 64 72 75
25 66 68 72 76 78
15 76 77 78 80 81
5 81 81 82 82 82
0 82 82 82 82 82
COEFFICIENTS OF UTILIZATION
% EFFECTIVE CEILING CAVITY REFLECTANCE
80 70 50
% WALL REFLECTANCE
50 30 10 50 30 10 50 30 10
0 77 77 77 66 66 66 47 47 47
1 66 64 61 57 55 53 40 39 37
2 58 53 49 50 46 43 35 33 31
3 51 45 41 44 39 36 31 28 26
4 45 39 34 38 34 30 27 24 22
5 39 33 29 34 29 25 24 21 18
6 35 29 25 30 25 22 21 18 16
7 31 25 21 27 22 19 19 16 13
8 28 22 18 24 20 16 17 14 12
9 25 20 16 22 17 14 16 12 10
10 23 18 14 20 15 12 14 11 9
ZONAL LUMEN SUMMARY
ZONE LUMENS % BARE LAMP %LUMINAIRE
0-90
90-180
0-180
4709
4439
270 5.7
94.3
100.0
4.6
75.2
79.8
Note: Shaded area indicates locations of emergency sections (emergency wiring
controls all lamps or optional battery pack controls one or two lamps).
*Note: Additional power mounts may be required for some runs with T5 HO
lamping options, longer runs, and runs with wiring options that are more complex.
Please consult factory for assistance.
COEFFICIENTS OF UTILIZATION
% EFFECTIVE CEILING CAVITY REFLECTANCE
80 70 50
% WALL REFLECTANCE
50 30 10 50 30 10 50 30 10
0 77 77 77 66 66 66 47 47 47
1 66 64 61 57 55 53 40 39 37
2 58 53 49 50 46 43 35 33 31
3 51 45 41 44 39 36 31 28 26
4 45 39 34 38 34 30 27 24 22
5 39 33 29 34 29 25 24 21 18
6 35 29 25 30 25 22 21 18 16
7 31 25 21 27 22 19 19 16 13
8 28 22 18 24 20 16 17 14 12
9 25 20 16 22 17 14 16 12 10
10 23 18 14 20 15 12 14 11 9
ZONAL LUMEN SUMMARY
ZONE LUMENS % BARE LAMP %LUMINAIRE
0-90
90-180
0-180
4709
4439
270 5.7
94.3
100.0
4.6
75.2
79.8