Lightolier Baselyte-BSL1 Indoor Furnishings User Manual


 
Lighting Systems Baselyte-BSL1
Page 2 of 8 2 Light T8 Direct/Indirect
Lightolier a Genlyte Company www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2005 Genlyte Group LLC • 0205 Rev.1
Job Information Type:
Performance
Candlepower Curve Candlepower Summary Coefficients of Utilization
-ODULE,ENGTH
-OUNTING$ISTANCE
-ODULE,ENGTH-OUNTING$ISTANCE
-ODULE,ENGTH-OUNTING$ISTANCE
@
@
@
Module Lengths & Mounting Distances
Note: Shaded area indicates locations of emergency sections (emergency wiring
controls all lamps or optional battery pack controls one or two lamps).
Joiner
BSLESW = suspended standard white
Dust Cover End Set
BSLJS = suspended joiner
BSLDCS = 4’ suspended dust cover
System Components & Accessories
Run Configuration
*Note: Additional power mounts may be required for some runs with T5 HO
lamping options, longer runs, and runs with wiring options that are more complex.
Please consult factory for assistance.
Report No: 2101580
Lamps: F32T8
Lumens per Lamp: 2950
Efficiency: 82.1%
Up: 76.9% Down: 23.1%
Zonal Lumen Summary
ZONE LUMENS %BARE LAMP %LUMINAIRE
Run
Length
4’
Module
8’
Module
12’
Module
Joiner End Set Mount
Power
Mount*
4’ run 1 1 1 1
8’ run 1 1 1 1
12’ run
1 1 1 1
16’ run
2 1 1 2 1
20’ run 1 1 1 1 2 1
24’ run 2 1 1 2 1
28’ run 2 1 2 1 3 1
32’ run 1 2 2 1 3 1






















CANDLEPOWER SUMMARY
ZONE CANDLEPOWER
DEG. 0 22.5 45 67.5 90
180 1045 1045 1045 1045 1045
175 1040 1038 1038 1035 1037
165 1001 994 1000 1003 1006
155 931 922 942 949 957
145 831 826 863 906 925
135 693 705 788 855 884
125 544 569 700 795 827
115 376 434 596 673 706
105 205 299 448 501 545
95 48 117 187 172 214
90 5 20 35 42 47
85 15 26 42 48 51
75 43 46 55 68 73
65 86 99 86 72 76
55 185 163 155 131 128
45 300 249 227 212 212
35 412 354 314 281 286
25 515 463 437 384 384
15 598 567 548 515 516
5 646 637 636 619 623
0 651 651 651 651 651
COEFFICIENTS OF UTILIZATION
% EFFECTIVE CEILING CAVITY REFLECTANCE
80 70 50
% WALL REFLECTANCE
50 30 10 50 30 10 50 30 10
0 82 82 82 73 73 73 56 56 56
1 72 69 66 64 61 59 49 47 46
2 63 58 54 56 52 49 43 40 38
3 55 50 45 49 45 41 38 35 32
4 49 43 38 44 39 35 34 30 27
5 44 37 33 39 34 30 30 26 24
6 39 33 28 35 30 26 27 23 21
7 35 29 25 31 26 22 25 21 18
8 32 26 22 29 23 20 22 19 16
9 29 23 19 26 21 18 20 17 14
10 26 21 17 24 19 16 19 15 13
ZONAL LUMEN SUMMARY
ZONE LUMENS % BARE LAMP %LUMINAIRE
0-90
90-180
0-180
4845
3728
1117 23.1
76.9
100.0
18.9
63.2
82.1
COEFFICIENTS OF UTILIZATION
% EFFECTIVE CEILING CAVITY REFLECTANCE
80 70 50
% WALL REFLECTANCE
50 30 10 50 30 10 50 30 10
0 82 82 82 73 73 73 56 56 56
1 72 69 66 64 61 59 49 47 46
2 63 58 54 56 52 49 43 40 38
3 55 50 45 49 45 41 38 35 32
4 49 43 38 44 39 35 34 30 27
5 44 37 33 39 34 30 30 26 24
6 39 33 28 35 30 26 27 23 21
7 35 29 25 31 26 22 25 21 18
8 32 26 22 29 23 20 22 19 16
9 29 23 19 26 21 18 20 17 14
10 26 21 17 24 19 16 19 15 13
ZONAL LUMEN SUMMARY
ZONE LUMENS % BARE LAMP %LUMINAIRE
0-90
90-180
0-180
4845
3728
1117 23.1
76.9
100.0
18.9
63.2
82.1