Lightolier AP2T8 Indoor Furnishings User Manual


 
Job Information Type:
"JSQPSU3PBE'BMM3JWFS."tt'BY
We reserve the right to change details of design, materials and finish.
XXXMJHIUPMJFSDPN½1IJMJQT(SPVQt
Lighting Systems ALETTA AP2T8
1BHFPG2 1BOFM4IJFME5-BNQTQFS'JYUVSF(SJE.PVOUFE
$
Performance
COEFFICIENTS OF UTILIZATOIN
% EFFECTIVE CEILING CAVITY REFLECTANCEE
CANDLEPOWER CURVE
80 70 50
WALL REFLECTANCE
70 50 30 70 50 30 50 30 10
0 81 81 81 79 79 79 76 76 76
1 74 71 68 72 69 66 66 64 62
2 67 62 57 66 60 56 58 54 51
3 62 54 49 60 53 48 51 47 43
4 56 48 42 55 47 42 46 41 37
5 52 43 37 51 43 37 41 36 32
6 48 39 33 47 39 33 37 32 29
7 45 36 30 44 35 30 34 29 26
8 42 33 27 41 32 27 31 27 23
9 39 30 25 38 30 25 29 24 21
10 37 28 23 36 28 23 27 22 19
20% FLOOR CAVITY REFLECTANCE
ROOM CAVITY RATIO
Zone Lumens % Lamp % Luminaire
0-90 4021 68.2 100
0-180 4021 68.2 100
DISTRIBUTION
Mounting Accessory
Drywall Conversion Kit
For Individual Units only
FK92X2
FK92X4
Lamp
Length
Lamp
Type
Lamp Rated
Output
Lamp
Wattage
Battery
Lumen Output
T5HO 4450* 54 1250*
T5 2600* 28 1325*
T8 2950 32 1100
T5HO 1750* 24 725*
T5 1200* 14 750*
T8 1350 17 650
* 25°C Rating
EM Pack Output Table
CANDLEPOWER
ZONE 0 22 45 67 90
DEG.
CANDELAS
90 0 0 0 0 0
85 44 75 87 72 75
75 205 225 349 435 469
65 421 397 439 549 599
55 688 624 556 568 617
45 951 917 808 758 742
35 1214 1193 1118 1034 1010
25 1455 1426 1379 1337 1325
15 1614 1603 1584 1560 1552
5 1689 1686 1682 1677 1673
0 1695 1695 1695 1695 1695
REPORT NO.: APE42T8.IES
LAMPS: 2 FO32/835
LUMENS: 2950
EFFICIENCY: 68.2%
– Conversion Kit for 2’ (60.96cm) Unit
– Conversion Kit for 4’ (121.92cm) Unit
4’
(121.92cm)
4’
(121.92cm)
4’
(121.92cm)
2’
(60.96cm)
2’
(60.96cm)
2’
(60.96cm)