Lightolier Aleron Series Indoor Furnishings User Manual


 
Job Information Type:
"JSQPSU3PBE'BMM3JWFS."tt'BY
We reserve the right to change details of design, materials and finish.
XXXMJHIUPMJFSDPN½1IJMJQT(SPVQt
Lighting Systems A-7
1BHFPG "MFSPOÜ4FSJFT-JHIU51FShDN4FDUJPO
$
Fixture Lengths and Mounting Locations
A1TES24ALD = Aluminum
A1TES24WHD = White
Dual Power Feed End Set
5 Wires (2-12 ga., 3-18ga.) on One End
A1TES24ALS = Aluminum
A1TES24WHS = White
Single Power Feed End Set
5 Wires (2-12 ga., 3-18ga.) on One End
AC36
Intermediate
36" (91.44cm) Cable Set
ALS24
Intermediate
24" (60.96cm) White Stem Set
ACC36X4
Intermediate 36" (91.44cm)
Cable & 4 Wire 18 ga.
Cord Set for Fluorescent Only
A1LAL= Aluminum
A1LWH = White
"L" Joiner Block
A1TAL = Aluminum
A1TWH = White
"T" Joiner Block
A1XAL = Aluminum
A1XWH = White
"X" Joiner Block
A1ILAL = Aluminum
A1ILWH = White
Inline Joiner Block
ATCAL = Aluminum
ATCWH = White
Track Adapter
7"
(17.78cm)
7" (17.78cm)
6"
(15.24cm)
12" (30.48cm)
7"
(17.78cm)
12"
(30.48cm)
12" (30.48cm)
12" (30.48cm)
4-7/16"
(11.27cm)
Mounting Accessories
3 Wires (2-12 ga. 1-18ga.) on One End
24" (60.96cm) Stems for Track
24" (60.96cm) Stems for Track
6"
(15.24cm)
6"
(15.24cm)
96” (243.84cm)
144” (365.76cm)
20’ 7” (627.38cm)
20-Foot
12’ 7” (383.54cm)
144” (365.76cm)
12-Foot
48” (121.92cm)
4-Foot
4’ 7” (139.87cm)
8-Foot
8’ 7” (261.62cm)
96” (243.84cm)
CANDLEPOWER CURVE
CANDLEPOWER
ZONE 0 22 45 67 90
DEG.
CANDELAS
Performance
REPORT NO: ITL50918
CAT NO: AIX4D54
LAMPS: 1-F54T5
LUMENS: 5000
EFFICIENCY: 62.7%
DISTRIBUTION
Zone
Lumens % Lamp % Luminaire
0-90 1216 24.3 38.8
90-180 1919 38.4 61.2
0-180 3136 62.7 100.0
580
435
290
145
0
10
20
30
40
50
60
70
80
9090
100
110
120
130
140
150
160
170
180
ROOM CAVITY RATIO
70 50 30 70 50 30 50 30 10
066 6666606060484848
158 5542535047403836
252 4743474339343129
347 4136433733302624
443 3631393328252320
539 3226352924232017
636 2823332621211714
733 2520302318191513
831 2318282116171311
929 2116261915151210
10 27 19 14 24 17 13 14 11 9
COEFFICIENTS OF UTILIZATION
% EFFECTIVE CEILING CAVITY REFLECTANCE
80 70 50
WALL REFLECTANCE
20% FLOOR CAVITY REFLECTANCE
180
175
165
155
145
135
125
115
105
95
90
85
75
65
55
45
35
25
15
5
0
371
372
359
343
344
338
312
246
137
37
10
50
98
135
171
201
226
244
256
263
262
371
372
359
339
325
306
268
198
166
143
112
105
123
146
175
204
229
247
257
263
262
371
370
357
333
304
276
227
374
355
253
205
174
156
183
201
208
225
244
257
262
262
371
369
358
334
299
257
288
533
436
313
246
202
190
220
229
226
229
244
257
261
262
371
368
364
346
316
276
239
584
507
388
268
228
202
216
236
233
229
234
249
259
262
4' (121.92cm)
Module
8' (243.84cm)
Module
12' (365.76cm)
Module
End Set Suspension
4' (121.92cm) Run 11
8' (243.84cm) Run 11
12' (365.76cm) Run 11
16' (487.68cm) Run 211
20' (609.60cm) Run 1111
24' (731.52cm) Run 211