Lighting Data 2-54W T5 High Output
1 198 176 118 60 28 14
2 158 142 90 52 24 10
3 103 94 69 41 22 10
4 68 63 49 33 20 12
5 40 38 30 22 14 8
6 26 25 21 16 12 8
7 17 16 14 11 8 6
8 11 11 10 8 6 5
9 887654
263 258 263
209 206 209
149 148 149
116 116 116
71 71 71
56 56 56
38 38 38
27 27 27
22 22 22
218 127 218
168 106 168
112 84 112
87 74 87
49 44 49
41 38 41
27 26 27
19 18 19
16 15 16
Footcandles on Wall
Track 3 Feet From Wall Single Unit Multiple Units
4
6
3
Distance From Ceiling
45˚
EXAMPLE: With track located 4 from wall and multiple units spaced
6 on center and aimed 45˚ from horizontal, the illumination on wall 4
from ceiling will be 79 f.c. beneath units and 70 f.c. between units.
1 113 101 71 39 17 6
2 114 104 77 47 25 12
3 87 80 62 40 24 13
4 63 59 47 34 22 13
5 46 44 36 27 19 13
6 31 30 25 20 14 10
7 22 21 18 15 11 8
8 16 15 13 11 9 7
9 11 11 10 8 7 6
145 143 145
164 163 164
136 135 136
112 112 112
93 93 93
66 66 66
50 50 50
41 42 42
31 32 32
123 106 123
136 123 136
110 103 110
91 88 91
77 75 77
54 53 54
41 40 41
35 34 35
26 26 26
114 76 114
123 92 123
97 79 97
79 70 79
66 62 66
46 43 46
35 34 35
30 29 30
23 22 23
Track 4 Feet From Wall Single Unit Multiple Units
4
5 6
4
Distance From Ceiling
45˚
Footcandles are average and rounded off and data for multiple units are based on a minimum of five units.
Footcandles on wall:
Beam Center
Beam Center
231 184 231
180 150 180
124 112 124
97 92 97
57 55 57
47 46 47
31 31 31
22 22 22
18 18 18
5
0 1 2 3 4 5
1 81 75 59 40 25 15
2 83 77 61 42 27 16
3 75 70 57 41 28 18
4 55 52 43 32 23 15
5 42 40 34 27 19 14
6 33 31 27 22 17 12
7 25 24 21 17 14 11
8 18 17 15 13 10 8
9 13 13 12 10 9 7
140 139 140
147 147 147
143 143 143
109 109 109
89 89 89
76 76 76
62 62 62
46 46 46
39 39 39
115 109 115
121 116 121
118 115 118
89 87 89
73 71 73
62 61 62
51 50 51
37 37 38
32 32 32
102 86 102
107 93 107
104 94 104
76 71 76
62 59 62
53 51 53
44 42 44
32 31 32
27 27 27
Track 5 Feet From Wall Single Unit Multiple Units
4
5 6
5
Distance From Ceiling
45˚
Beam Center
Lamp Information:
2 X 54W T5 High Output
Mini Bi-Pin Fluorescent (9476)
1 x 54W T5 High Output
Mini Bi Pin Fluorescent (9477)
One Lamp, with louver,
aimed 45˚ down.
Two Lamps, without louver,
aimed 45˚ up.
Two Lamps, with louver,
aimed 45˚ down.
0˚ 30˚
90˚
60˚
180˚ 150˚
120˚
90˚
0˚ 30˚
90˚
60˚
Lytespan
®
Track Lighting System 9476
Page 2 of 2 PowerWash
T5 4 Foot Track Mounted 54 Watt High Output Fluorescent
Lightolier a Genlyte Thomas Company www.lightolier.com
631 Airport Road, Fall River, MA 02720 (508) 679-8131 Fax (508) 674-4710