Lightolier 8292WE Indoor Furnishings User Manual


 
Lighting Data
1 176 137 73 31 13 7
2 113 95 62 33 14 5
3 72 64 48 29 15 7
4 49 46 37 25 15 8
5 34 32 26 20 13 8
6 24 23 19 15 11 7
7 16 15 13 11 8 6
8 11 18 9 8 6 5
9 877654
200 156 208
141 127 141
103 101 103
83 83 83
62 61 62
50 50 50
37 36 37
27 27 27
21 21 21
186 66 186
116 65 116
78 58 78
60 55 60
42 40 43
35 34 36
26 25 26
19 18 19
15 15 15
Footcandles on Wall
Track 3 Feet From Wall Single Unit Multiple Units
4
6
3
Distance From Ceiling
50˚
EXAMPLE: With track located 4’ from wall and multiple units spaced
6’ on center and aimed 50˚ from horizontal, the illumination on wall 4’
from ceiling will be 53 f.c. beneath units and 50 f.c. between units.
1 89 78 51 26 11 4
2 82 72 52 32 17 8
3 56 51 40 28 17 10
4 41 38 32 24 16 10
5 31 29 25 21 15 10
6 23 22 20 16 13 9
7 18 17 15 13 10 8
8 14 13 12 10 9 7
9 10 10 9 8 7 6
106 102 107
116 109 116
92 90 92
77 76 77
66 65 66
53 53 53
44 44 44
37 37 37
30 30 30
94 71 94
97 83 97
74 70 74
62 61 62
53 53 53
43 42 43
36 35 36
31 30 31
24 24 25
89 49 89
88 62 88
64 56 64
53 50 53
45 45 45
36 36 36
30 30 30
26 26 26
21 21 21
Track 4 Feet From Wall Single Unit Multiple Units
4
5 6
4
Distance From Ceiling
50˚
Footcandles are average and rounded off and data for multiple units are based on a minimum of five units.
Footcandles on wall:
0 1 2 3 4 5
0 1 2 3 4 5
Beam Center
Beam Center
Lamp Information:
70W CDM or CMH T6 Double Ended Metal Halide.
Initial Lumens: 6200 to 7000
CRI: 85
Rated Avg. life: 12,000 hrs.
192 102 192
123 93 123
86 78 86
68 68 68
50 49 50
41 40 41
30 29 30
22 22 22
17 17 17
5
Lytespan
®
Track Lighting System 8292WE
Page 2 of 2 PowerArc
TM
Double Ended Metal Halide Wall Washer
Lightolier a Genlyte Thomas Company www.lightolier.com
631 Airport Road, Fall River, MA 02720 (508) 679-8131 Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2003 Genlyte Thomas Group LLC (Lightolier Division) B0303
Job Information Type: