Lightolier 8226WH Indoor Furnishings User Manual


 
Lytespan
®
Track Lighting System 8226WH
Page 2 of 2 PAR-Tech
TM
Cylinder 20 Shade
Lightolier a Genlyte Thomas Company www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2002 Genlyte Thomas Group LLC (Lightolier Division) • A0902
Job Information Type:
Lighting Data
600 2,500
35W PAR20
WFL (Halogen) 40°
3' 67 2.2' 2.2'
5' 24 3.6' 3.6'
7' 12 5.1' 5.1'
9' 7 6.6' 6.6'
3' 1.7' 43 3.0' 2.5'
5' 2.8' 16 5.1' 4.2'
7' 4.0' 8 7.1' 5.9'
9' 5.2' 5 9.1' 7.6'
2' 2.0' 53 3.4' 2.1'
3' 3.0' 24 5.0' 3.1'
4' 4.0' 13 6.7' 4.1'
5' 5.0' 8 8.4' 5.1'
1' 1.7' 75 4.8' 1.5'
2' 3.5' 19 9.7' 2.9'
3' 5.2' 8 14.5' 4.4'
4' 6.9' 5 19.3' 5.8'
3' 100 1.6' 1.6'
5' 38 2.7' 2.7'
7' 18 3.8' 3.8'
9' 11 4.8' 4.8'
3' 1.7' 65 2.2' 1.6'
5' 2.9' 23 3.7' 3.1'
7' 4.0' 12 5.1' 4.3'
9' 5.2' 7 6.6' 5.6'
2' 2.0' 80 2.3' 1.5'
3' 3.0' 35 3.5' 2.3'
4' 4.0' 20 4.6' 3.0'
5' 5.0' 13 5.8' 3.8'
1' 1.7' 113 2.7' 1.1'
2' 3.5' 28 5.5' 2.1'
3' 5.2' 13 8.2' 3.2'
4' 6.9' 7 10.9' 4.3'
900 2,500
35W PAR20 FL
(Halogen) 30°
6' 167 0.8' 0.8'
8' 94 1.1' 1.1'
10' 60 1.4' 1.4'
12' 42 1.7' 1.7'
5' 2.9' 156 0.9' 0.8'
7' 4.0' 80 1.3' 1.1'
9' 5.2' 48 1.7' 1.5'
11' 6.4' 32 2.1' 1.8'
3' 3.0' 236 0.8' 0.6'
5' 5.0' 85 1.4' 1.0'
7' 7.0' 43 2.0' 1.4'
9' 9.0' 26 2.5' 1.8'
2' 3.5' 188 1.1' 0.6'
3' 5.2' 83 1.7' 0.8'
4' 6.9' 47 2.3' 1.1'
5' 8.7' 30 2.8' 1.4'
6,000 2,000
50W PAR20
NSP (Halogen) 8°
DFC L W
DC FC L W DC FC L W DC FC L W
Beam Spread Beam Center Rated
50% Max. CP C.P. Candelas Life-Hrs
1,850 2,000
50W PAR20
NFL (Halogen) 27°
4' 116 1.9' 1.9'
6' 51 2.9' 2.9'
8' 29 3.8' 3.8'
10' 19 4.8' 4.8'
3' 1.7' 134 2.0' 1.7'
5' 2.9' 48 3.3' 2.8'
7' 4.0' 25 4.6' 3.9'
9' 5.2' 15 5.9' 5.0'
3' 3.0' 73 3.1' 2.0'
4' 4.0' 41 4.1' 2.7'
5' 5.0' 26 5.1' 3.4'
6' 6.0' 18 6.1' 4.1'
1' 1.7' 231 2.3' 1.0'
2' 3.5' 58 4.8' 1.9'
3' 5.2' 26 7.0' 2.9'
4' 6.9' 14 9.3' 3.8'
6' 89 1.6' 1.6'
8' 50 2.1' 2.1'
10' 32 2.8' 2.8'
12' 22 3.2' 3.2'
5' 2.9' 83 1.8' 1.5'
7' 4.0' 42 2.5' 2.1'
9' 5.2' 26 3.2' 2.7'
11' 6.4' 17 3.9' 3.3'
3' 3.0' 126 1.6' 1.1'
5' 5.0' 45 2.7' 1.9'
7' 7.0' 23 3.8' 2.6'
9' 9.0' 14 4.8' 3.4'
2' 3.5' 100 2.2' 1.1'
3' 5.2' 44 3.3' 1.6'
4' 6.9' 25 4.4' 2.1'
5' 8.7' 16 5.6' 2.6'
3,200 2,000
50W PAR20
SP (Halogen) 15°
6' 83 0.8' 0.8'
8' 47 1.1' 1.1'
10' 30 1.4' 1.4'
12' 21 1.7' 1.7'
5' 2.9' 78 0.9' 0.8'
7' 4.0' 40 1.3' 1.1'
9' 5.2' 24 1.7' 1.5'
11' 6.4' 16 2.1' 1.8'
3' 3.0' 118 0.8' 0.6'
5' 5.0' 42 1.4' 1.0'
7' 7.0' 22 2.0' 1.4'
9' 9.0' 13 2.5' 1.8'
2' 3.5' 94 1.1' 0.6'
3' 5.2' 42 1.7' 0.8'
4' 6.9' 23 2.3' 1.1'
5' 8.7' 15 2.8' 1.4'
3,000 2,500
35W PAR20 NSP
(Halogen) 8°
FC
D
L
C
A
W
L
W
FC
D
FC
L
C
D
A
LAMP 0˚ AIMING ANGLE A=30˚ AIMING ANGLE A=45˚ AIMING ANGLE A=60˚ AIMING ANGLE
Aiming Angle 30˚, 45˚ or 60˚ Horizontal 30˚, 45˚ or 60˚ Vertical
L Beam Length
W Beam Width
C Distance to center beam
D Distance
A Aiming Angle
FC Footcandles
L and W are the outer points where the candle
power drops to 50% of the maximum. FC are the
initial footcandles at the center of the beam.