Lighting Data
600 2,500
35W PAR20
WFL (Halogen) 40°
3 67 2.2 2.2
5 24 3.6 3.6
7 12 5.1 5.1
9 7 6.6 6.6
3 1.7 43 3.0 2.5
5 2.8 16 5.1 4.2
7 4.0 8 7.1 5.9
9 5.2 5 9.1 7.6
2 2.0 53 3.4 2.1
3 3.0 24 5.0 3.1
4 4.0 13 6.7 4.1
5 5.0 8 8.4 5.1
1 1.7 75 4.8 1.5
2 3.5 19 9.7 2.9
3 5.2 8 14.5 4.4
4 6.9 5 19.3 5.8
3 100 1.6 1.6
5 38 2.7 2.7
7 18 3.8 3.8
9 11 4.8 4.8
3 1.7 65 2.2 1.6
5 2.9 23 3.7 3.1
7 4.0 12 5.1 4.3
9 5.2 7 6.6 5.6
2 2.0 80 2.3 1.5
3 3.0 35 3.5 2.3
4 4.0 20 4.6 3.0
5 5.0 13 5.8 3.8
1 1.7 113 2.7 1.1
2 3.5 28 5.5 2.1
3 5.2 13 8.2 3.2
4 6.9 7 10.9 4.3
900 2,500
35W PAR20 FL
(Halogen) 30°
6 167 0.8 0.8
8 94 1.1 1.1
10 60 1.4 1.4
12 42 1.7 1.7
5 2.9 156 0.9 0.8
7 4.0 80 1.3 1.1
9 5.2 48 1.7 1.5
11 6.4 32 2.1 1.8
3 3.0 236 0.8 0.6
5 5.0 85 1.4 1.0
7 7.0 43 2.0 1.4
9 9.0 26 2.5 1.8
2 3.5 188 1.1 0.6
3 5.2 83 1.7 0.8
4 6.9 47 2.3 1.1
5 8.7 30 2.8 1.4
6,000 2,000
50W PAR20
NSP (Halogen) 8°
DFC L W
DC FC L W DCFC L W DC FC L W
Beam Spread Beam Center Rated
50% Max. CP C.P. Candelas Life-Hrs
1,850 2,000
50W PAR20
NFL (Halogen) 27°
4 116 1.9 1.9
6 51 2.9 2.9
8 29 3.8 3.8
10 19 4.8 4.8
3 1.7 134 2.0 1.7
5 2.9 48 3.3 2.8
7 4.0 25 4.6 3.9
9 5.2 15 5.9 5.0
3 3.0 73 3.1 2.0
4 4.0 41 4.1 2.7
5 5.0 26 5.1 3.4
6 6.0 18 6.1 4.1
1 1.7 231 2.3 1.0
2 3.5 58 4.8 1.9
3 5.2 26 7.0 2.9
4 6.9 14 9.3 3.8
6 89 1.6 1.6
8 50 2.1 2.1
10 32 2.8 2.8
12 22 3.2 3.2
5 2.9 83 1.8 1.5
7 4.0 42 2.5 2.1
9 5.2 26 3.2 2.7
11 6.4 17 3.9 3.3
3 3.0 126 1.6 1.1
5 5.0 45 2.7 1.9
7 7.0 23 3.8 2.6
9 9.0 14 4.8 3.4
2 3.5 100 2.2 1.1
3 5.2 44 3.3 1.6
4 6.9 25 4.4 2.1
5 8.7 16 5.6 2.6
3,200 2,000
50W PAR20
SP (Halogen) 15°
6 83 0.8 0.8
8 47 1.1 1.1
10 30 1.4 1.4
12 21 1.7 1.7
5 2.9 78 0.9 0.8
7 4.0 40 1.3 1.1
9 5.2 24 1.7 1.5
11 6.4 16 2.1 1.8
3 3.0 118 0.8 0.6
5 5.0 42 1.4 1.0
7 7.0 22 2.0 1.4
9 9.0 13 2.5 1.8
2 3.5 94 1.1 0.6
3 5.2 42 1.7 0.8
4 6.9 23 2.3 1.1
5 8.7 15 2.8 1.4
3,000 2,500
35W PAR20 NSP
(Halogen) 8°
FC
D
L
C
A
W
L
W
FC
D
FC
L
C
D
A
LAMP 0˚ AIMING ANGLE A=30˚ AIMING ANGLE A=45˚ AIMING ANGLE A=60˚ AIMING ANGLE
Aiming Angle 30˚, 45˚ or 60˚ Horizontal 30˚, 45˚ or 60˚ Vertical
L Beam Length
W Beam Width
C Distance to center beam
D Distance
A Aiming Angle
FC Footcandles
L and W are the outer points where the candle
power drops to 50% of the maximum. FC are the
initial footcandles at the center of the beam.