Lightolier is a Philips group brand
Job Information Type:
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2008 Philips Group • A0708
Calculite
®
CFL Lensed Downlight 8091
Page 2 of 2 6" Aperture Triple Tube Horizontal Lamp
32W Clear Cone (CL)
Spacing Ratio = 1.2
CERTIFIED TEST REPORT NO. 0075FR
COMPUTED BY LSI PROGRAM **TEST-LITE**
CALCULITE 6" DIAMETER RECESSED FLUORESCENT LENSED DOWNLIGHT
SEMI-SPECULAR REFLECTOR WITH CLEAR CONE AND FRESNEL LENS
LUMEN RATING = 2400 LMS.
1-32W PL-T LAMP,
60
50
40
30
20
10
15 30 45 60 75 90 105 120
AREA PER FIXTURE IN SQUARE FEET
45 678 91011
CENTER TO CENTER DISTANCE OF FIXTURES IN FEET
This quick calculator chart determines the number and spacing of 1 It.- 32W PL-T units
with fresnel lens and clear reflector, for any level of illumination. Conversion factors:
Opal diffuser, fc x 0.8; Clear lens, fc x 1.0. 1 It.- 26W PLT : Fresnel Lens, fc x 0.8; Opal
Diffuser, fc x 0.65; Clear lens fc x 0.8.
INITIAL FOOTCANDLES
ROOM SURFACE REFLECTANCES:
80% Ceiling; 50% Wall; 20% Floor
2400 Lumens Per Lamp
RCR= 1 (Rm. Width= 10xMtg. Ht. above work plane)
RCR= 5 (Rm. Width= 2xMtg. Ht. above work plane)
RCR=10 (Rm. Width= Mtg. Ht. above work plane)
32W White Cone (WH)
Quick Calculator
60
50
40
30
20
10
15 30 45 60 75 90 105
AREA PER FIXTURE IN SQUARE FEET
345678 910
CENTER TO CENTER DISTANCE OF FIXTURES IN FEET
This quick calculator chart determines the number and spacing of 1 It.- 32W PL-T units
with fresnel lens and white cone, for any level of illumination. Conversion factors: Opal
diffuser, fc x 0.8; Clear lens, fc x 1.0. 1 It.- 26W PLT : Fresnel Lens, fc x 0.8; Opal Diffuser,
fc x 0.65; Clear lens fc x 0.8.
INITIAL FOOTCANDLES
Spacing Ratio = 1.1
CERTIFIED TEST REPORT NO. 0072FR
COMPUTED BY LSI PROGRAM **TEST-LITE**
CALCULITE 6" DIAMETER RECESSED FLUORESCENT LENSED DOWNLIGHT
SEMI-SPECULAR REFLECTOR WITH WHITE CONE AND FRESNEL LENS
LUMEN RATING = 2400 LMS.
1-32W PL-T LAMP,
Coefficients Of Utilization
% EFFECTIVE CEILING CAVITY REFLECTANCE
80 70 50 30 10 0
% WALL REFLECTANCE
50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0
1 .56 .55 .54 .56 .54 .53 .53 .52 .51 .51 .51 .50 .50 .49 .48 .48
2 .52 .50 .48 .51 .49 .48 .50 .48 .47 .48 .47 .46 .47 .46 .45 .44
3 .48 .46 .44 .48 .45 .43 .46 .44 .43 .45 .43 .42 .44 .43 .41 .40
4 .45 .42 .40 .44 .42 .39 .43 .41 .39 .42 .40 .38 .41 .39 .38 .37
5 .42 .38 .36 .41 .38 .36 .40 .37 .35 .39 .37 .35 .38 .36 .35 .34
6 .38 .35 .33 .38 .35 .32 .37 .34 .32 .36 .34 .32 .36 .33 .32 .31
7 .35 .32 .30 .35 .32 .29 .34 .31 .29 .33 .31 .29 .33 .31 .29 .28
8 .32 .29 .27 .32 .29 .27 .32 .29 .27 .31 .28 .26 .30 .28 .26 .25
9 .30 .27 .24 .30 .26 .24 .29 .26 .24 .29 .26 .24 .28 .26 .24 .23
10 .28 .24 .22 .27 .24 .22 .27 .24 .22 .26 .24 .22 .26 .23 .22 .21
20% FLOOR CAVITY REFLECTANCE
Conversion Factors: 1 Lt-32W PLT: Opal Diffuser, CU x 0.8; Clear Lens, CU x 1.0.
1 Lt-26W PLT: Fresnel Lens, CU x 1.1; Opal Diffuser, CU x 0.9; Clear Lens, CU x 1.1.
ROOM CAVITY RATIO
Coefficients Of Utilization
% EFFECTIVE CEILING CAVITY REFLECTANCE
80 70 50 30 10 0
% WALL REFLECTANCE
50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0
1 .48 .46 .45 .47 .46 .44 .45 .44 .43 .43 .43 .42 .42 .41 .41 .40
2 .44 .42 .40 .42 .41 .39 .41 .40 .38 .40 .39 .38 .39 .38 .37 .36
3 .40 .37 .35 .39 .37 .35 .38 .38 .34 .37 .35 .34 .36 .33 .33 .33
4 .37 .34. 32 .36 .34 .32 .35 .33 .31 .34 .32 .31 .34 .32 .30 .30
5 .34 .31 .29 .33 .31 .28 .33 .30 .28 .32 .30 .28 .31 .29 .28 .27
6 .31 .28 .26 .31 .28 .26 .30 .28 .26 .29 .27 .25 .25 .27 .25 .25
7 .29 .26 .23 .28 .25 .23 .25 .25 .23 .27 .25 .23 .27 .25 .23 .22
8 .26 .23 .21 .26 .23 .21 .26 .23 .21 .25 .23 .21 .25 .23 .21 .20
9 .24 .21 .19 .24 .21 .19 .24 .21. 19 .23 .21 .19 .23 .21 .29 .18
10 .23 .20 .18 .22 .20 .18 .22 .19 .18 .22 .19 .17 .21 .19 .19 .17
20% FLOOR CAVITY REFLECTANCE
Conversion Factors: 1 Lt-32W PLT: Opal Diffuser, CU x 0.8; Clear Lens, CU x 1.0.
1 Lt-26W PLT: Fresnel Lens, CU x 1.1; Opal Diffuser, CU x 0.9; Clear Lens, CU x 1.1.
ROOM CAVITY RATIO
Quick Calculator
ROOM SURFACE REFLECTANCES:
80% Ceiling; 50% Wall; 20% Floor
2400 Lumens Per Lamp
RCR= 1 (Rm. Width= 10xMtg. Ht. above work plane)
RCR= 5 (Rm. Width= 2xMtg. Ht. above work plane)
RCR=10 (Rm. Width= Mtg. Ht. above work plane)
CANDLEPOWER
ANGLE ALONG 22.5 45 67.5 ACROSS LUMENS
0 780 780 780 780 780
5 773 778 779 782 785 37
10 758 768 774 781 790
15 736 732 738 753 776 104
20 680 647 664 699 739
25 589 552 591 633 688 140
30 499 489 530 572 630
35 413 425 446 481 536 143
40 334 358 364 386 425
45 268 286 288 304 323 115
50 210 232 232 239 244
55 87 105 109 116 119 55
60 32 38 42 45 47
65 689911 7
70 11122
75 111110
80 11111
85 011010
90 01101
ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS % LAMP%LUMINAIRE
0-30 585 24.40 47.62
0-40 886 36.92 72.06
0-60 1216 50.67 98.90
0-90 1229 51.24 100.00
40-90 343 14.32 27.94
60-90 13 .57 1.10
90-180 0 .00 .00
0-180 1229 51.24 100.00
CANDLEPOWER
ANGLE ALONG 22.5 45 67.5
ACROSS LUMENS
0 656 656 656 656 656
5 649 654 657 660 662 31
10 626 639 650 660 669
15 588 605 622 639 654 87
20 525 546 567 592 617
25 452 479 501 526 563 116
30 378 419 432 450 490
35 312 363 361 370 405 114
40 256 303 290 297 322
45 200 233 225 231 244 89
50 144 156 165 171 180
55 99 115 115 117 120 53
60 66 74 76 77 79
65 46 48 49 50 52 26
70 35 36 37 38 39
75 26 27 27 27 29 14
80 16 17 17 19 19
85 799995
90 11111
ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS %
LAMP%LUMINAIRE
0-30 468
19.51 44.30
0-40 697
29.07 66.29
0-60 956
40.28 91.86
0-90
1052 43.86 100.00
40-90 354 14.76 33.71
60-90 85 3.57 8.14
90-180 0 .00 .00
0-180 1052 43.86 100.00
150
120
60
30
60
30
180
0
600
900
300
Across
45
Along
9090
** EFFICIENCY = 51.2% **
150
120
60
30
60
30
180
0
600
900
300
Across
45
Along
9090
** EFFICIENCY = 43.9% **