CFL Lensed Wall Washer 8046
Page 2 of 2 6" Aperture Triple Tube Vertical Lamp
2' From Wall-3' On Center
1271627
2362736
3 26 25 26
4191919
5141414
6111111
7999
8777
9666
2' From Wall-2' On Center
1333033
2484648
3383838
4282828
5202020
6151515
7121212
8101010
9888
2' From Wall-2' On Center
1242224
2313131
3282828
4222222
5171717
6131313
7101110
8999
9777
3' From Wall-4' On Center
1646
211911
3111011
4111011
5999
6888
7777
8666
9666
3' From Wall-3' On Center
1767
2131213
3141414
4141414
5121212
6101110
7999
8888
9777
Lighting Data
Footcandles On Wall: Multiple 26w Units
3"
2"
20 f.c.
19 f.c.
3'
2' From Wall-3' On Center
1191219
2231923
3 20 19 20
4151515
5121212
6999
7888
8666
9666
Footcandles On Wall: Multiple 32w Units
3' From Wall-3' On Center
1989
2191819
3222122
4191919
5161616
6131313
7111111
8999
9888
3' From Wall-4' On Center
1858
2161216
3171517
4151415
5121212
6101010
7888
8777
9666
3"
2"
25 f.c.
26 f.c.
3'
EXAMPLE: With multiple clear reflector units located 2' from wall and
spaced 3' on center, the illumination on the wall 3' down from ceiling
will be 19 f.c. beneath units and 20 f.c. between units.
EXAMPLE: With multiple clear reflector units located 2' from wall and
spaced 3' on center, the illumination on the wall 3' down from ceiling
will be 26 f.c. beneath units and 25 f.c. between units.
Footcandle values are averaged and rounded off and based on minimum of five units.