Lightolier 1101IE Indoor Furnishings User Manual


 
Lightolier a Genlyte company www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2007 Genlyte Group LLC • A1207
Job Information Type:
Lytecaster
®
Performance Recessed CFL Downlighting 1101IE
Page 2 of 2 6 ¾" Aperture Vertical Open Downlight, Compact Fluorescent, Performance Series,
Integrated Emergency, Reflector Trim
42W G.E. 4 PIN TRIPLE BIAX, LUMEN RATING = 3200 LMS, CL FINISH TRIM
32W G.E. 4 PIN TRIPLE BIAX, LUMEN RATING = 2200 LMS, CL FINISH TRIM
26W G.E. 4 PIN TRIPLE BIAX, LUMEN RATING = 1710 LMS, CL FINISH TRIM
181
363
544
725
1
400
800
1200
1600
60˚
30˚
ZONAL LUMENS AND PERCENTAGES
Zone Lumens %Lamp %Fixt
0-30 1043.18 32.6 49.1
0-40 1579.97 49.4 74.3
0-60 2119.92 66.2 99.7
0-90 2125.77 66.4 100
90-120 0 0 0
90-130 0 0 0
90-150 0 0
90-180 2125.77 66.4 100
**
Efficiency = 66.4%
**
COEFFICIENTS OF UTILIZATION
Ceiling 80% 70% 50% 30%
Wall 70 50 30 10 50 10 50 10 50 10 0
RCR Zonal Cavity Method - Effective Floor Reflectance = 20%
Room Cavity Ratio
0 79 79 79 79 77 77 74 74 71 71 66
1 75 73 71 69 71 68 69 66 66 64 61
2 70 67 63 61 65 60 63 59 61 57 55
3 66 61 57 54 60 53 58 53 56 52 50
4 62 56 51 48 55 48 53 47 52 47 45
5 58 51 47 43 51 43 49 43 48 42 41
6 54 47 43 39 47 39 46 39 41 38 37
7 51 44 39 36 43 36 42 35 41 35 34
8 48 40 36 33 40 33 39 32 38 32 31
36 45 38 33 30 37 30 37 30 36 30 29
10 42 35 31 28 35 28 34 28 34 27 26
Determined In Accordance With Current IES Published Procedures
Luminaire Input Watts = 44
ZONAL LUMEN SUMMARY
Zone Lumens
0-10
143.51
10-20
379.14
20-30
520.52
30-40
536.79
40-50
411.63
50-60
128.32
60-70
4.54
70-80
1.31
80-90
0
90-100
0
100-110
0
110-120
0
120-130
0
130-140
0
140-150
0
150-160
0
160-170
0
170-180
0
CANDLEPOWER SUMMARY
Angle 0˚ CP
0 1482
5 1521
10 1468
15 1354
20 1226
25 1137
30 1017
35 864
40 699
45 538
50 363
55 112
60 13
65 3
70 2
75 1
80 0
85 0
90 0
SC = 1.1
CERTIFIED TEST REPORT NO. 3278FR
COMPUTED BY LSI PROGRAM
**TEST-LITE**
ZONAL LUMENS AND PERCENTAGES
Zone Lumens %Lamp %Fixt
0-30 590.62 26.8 40.7
0-40 962.92 43.8 66.4
0-60 1441.31 65.5 99.3
0-90 1450.77 65.9 100
90-120 0 0 0
90-130 0 0 0
90-150 0 0
90-180 1450.77 65.9 100
**
Efficiency = 65.9 %
**
COEFFICIENTS OF UTILIZATION
Ceiling 80% 70% 50% 30%
Wall 70 50 30 10 50 10 50 10 50 10 0
RCR Zonal Cavity Method - Effective Floor Reflectance = 20%
Room Cavity Ratio
0 79 79 79 79 77 77 73 73 70 70 66
1 74 72 70 68 70 67 68 65 65 63 60
2 69 65 62 59 64 58 62 57 60 56 53
3 64 59 55 51 58 51 56 50 54 49 47
4 60 53 49 45 53 45 51 44 50 44 42
5 56 49 44 40 48 40 47 40 45 39 38
6 52 44 39 36 44 36 43 35 42 35 34
7 48 41 36 32 40 32 39 32 38 32 30
8 45 37 32 29 37 29 36 29 35 29 27
36 42 34 30 26 34 26 33 26 33 26 25
10 40 32 27 24 32 24 31 24 30 24 23
Determined In Accordance With Current IES Published Procedures
Luminaire Input Watts = 33
ZONAL LUMEN SUMMARY
Zone Lumens
0-10
68. 98
10-20
200.27
20-30
321.37
30-40
372.3
40-50
313.27
50-60
165.12
60-70
8.4
70-80
1.05
80-90
0
90-100
0
100-110
0
110-120
0
120-130
0
130-140
0
140-150
0
150-160
0
160-170
0
170-180
0
CANDLEPOWER SUMMARY
Angle 0˚ CP
0 686
5 719
10 729
15 706
20 697
25 702
30 671
35 601
40 508
45 408
50 306
55 197
60 37
65 4
70 2
75 1
80 0
85 0
90 0
181
363
544
725
1
200
400
600
800
60˚
30˚
SC = 1.3
CERTIFIED TEST REPORT NO. 3280FR
COMPUTED BY LSI PROGRAM
**TEST-LITE**
1
200
400
600
800
60˚
30˚
SC = 1.3
CERTIFIED TEST REPORT NO. 3282FR
COMPUTED BY LSI PROGRAM
**TEST-LITE**
ZONAL LUMENS AND PERCENTAGES
Zone Lumens %Lamp %Fixt
0-30 530.36 31 47.5
0-40 842.82 49.3 75.4
0-60 1115.14 65.2 99.8
0-90 1117.5 65.4 100
90-120 120 0 0
90-130 0 0 0
90-150 0 0
90-180 1117.5 65.4 100
**
Efficiency = 65.4 %
**
COEFFICIENTS OF UTILIZATION
Ceiling 80% 70% 50% 30%
Wall 70 50 30 10 50 10 50 10 50 10 0
RCR Zonal Cavity Method - Effective Floor Reflectance = 20%
Room Cavity Ratio
0 78 78 78 78 76 76 73 73 70 70 65
1 74 71 70 68 70 67 67 65 65 63 60
2 69 65 62 60 64 59 62 58 60 56 54
3 65 60 56 53 59 52 57 52 55 51 49
4 61 55 50 47 54 47 52 46 51 46 44
5 57 50 46 42 50 42 48 42 47 41 40
6 53 46 42 38 46 38 45 38 44 37 36
7 50 43 38 35 42 35 41 34 40 34 33
8 47 39 35 32 39 31 38 31 37 31 30
36 44 36 32 29 36 29 35 29 35 29 27
10 41 34 29 27 41 29 34 27 33 26 25
Determined In Accordance With Current IES Published Procedures
Luminaire Input Watts = 28
ZONAL LUMEN SUMMARY
Zone Lumens
0-10 63.18
10-20 181.85
20-30 285.32
30-40 312.46
40-50 214.19
50-60 58.13
60-70 1.96
70-80 .39
80-90 0
90-100 0
100-110 0
110-120 0
120-130 0
130-140 0
140-150 0
150-160 0
160-170 0
170-180 0
CANDLEPOWER SUMMARY
Angle 0˚ CP
0
632
5
660
10
666
15
642
20
628
25
625
30
585
35
507
40
403
45
281
50
153
55
57
60
5
65
2
70
1
75
0
80
0
85
0
90
0