Lightolier 1101HLIE Indoor Furnishings User Manual


 
Performance Recessed CFL Downlighting 110 1HL IE
Page 2 of 2 6 ¾" Aperture Horizontal Lensed, Compact Fluorescent, Performance Series,
Integrated Emergency, Reflector Trim
Job Information Type:
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2008 Philips Group • B0908
Lightolier is a Philips group brand
COEFFICIENTS OF UTILIZATION
Ceiling 80% 70% 50% 30%
Wall 70 50 30 10 50 10 50 10 50 10 0
RCR Zonal Cavity Method - Effective Floor Reflectance = 20%
Room Cavity Ratio
0 54 54 54 54 53 53 51 51 49 49 46
1 51 50 49 47 49 47 47 45 45 44 42
2 48 46 43 41 45 41 43 40 42 39 38
3 45 42 39 37 41 36 40 36 39 35 34
4 42 38 35 33 38 33 36 32 36 32 31
5 40 35 32 29 34 29 34 29 33 29 28
6 37 32 29 27 32 27 31 26 30 26 25
7 35 30 27 24 29 24 29 24 28 24 23
8 33 28 24 22 27 24 22 27 22 26 21
9 31 26 23 20 25 20 25 20 25 20 19
10 29 24 21 19 24 19 23 19 23 19 18
Determined In Accordance With Current IES Published Procedures
Luminaire Input Watts = 33.0
32W TRIPLE TUBE LAMP, LUMEN RATING = 2200 LMS, ELECTRONIC BALLAST, CL FINISH TRIM WITH CLEAR LENS
181
363
544
725
0
195
390
585
780
60˚
30˚
COEFFICIENTS OF UTILIZATION
Ceiling 80% 70% 50% 30%
Wall 70 50 30 10 50 10 50 10 50 10 0
RCR Zonal Cavity Method - Effective Floor Reflectance = 20%
Room Cavity Ratio
0 63 63 63 63 61 61 59 59 56 56 53
1 59 58 56 55 56 55 52 52 51 51 48
2 56 52 50 48 52 49 50 46 48 45 43
3 52 48 45 42 47 44 46 41 44 40 39
4 49 44 40 37 43 40 42 37 41 36 35
5 45 40 36 33 39 36 38 33 37 33 31
6 42 37 33 30 36 33 35 30 35 30 29
7 40 34 30 27 33 30 33 27 32 27 26
8 37 31 28 25 31 27 30 25 30 25 24
9 35 29 25 23 29 25 28 23 28 23 22
10 33 27 23 21 27 23 26 21 26 21 20
Determined In Accordance With Current IES Published Procedures
Luminaire Input Watts = 35
CANDLEPOWER SUMMARY
Angle 0˚ CP
0 777
5 763
10 734
15 688
20 644
25 582
30 490
35 432
40 386
45 359
50 231
55 113
60 30
65 7
70 3
75 3
80 2
85 2
90 2
ZONAL LUMEN SUMMARY
Zone Lumens
0-10
72.01
10-20
198.72
20-30
275.06
30-40
272.29
40-50
232.89
50-60
96.02
60-70
10.23
70-80
2.99
80-90
2.08
90-100
0
100-110
0
110-120
0
120-130
0
130-140
0
140-150
0
150-160
0
160-170
0
170-180
0
ZONAL LUMENS AND PERCENTAGES
Zone Lumens %Lamp %Fixt
**
Efficiency = 52.7%
**
0-30 545.79 24.8 47
0-40 818.08 37.2 70.4
0-60 1146.99 52.1 98.7
0-90 1162.29 52.8 100
90-120 0 0 0
90-150 0 0 0
90-180 0 0 0
0-180 0 0 0
SC = 1.1
CERTIFIED TEST REPORT NO. 3352FR
COMPUTED BY LSI PROGRAM
**TEST-LITE**
32W TRIPLE TUBE LAMP, LUMEN RATING = 2200 LMS, ELECTRONIC BALLAST, CL FINISH TRIM WITH FRESNEL LENS
150
2
1
300
450
600
0
186
371
557
742
1 – 90°
2 – 0°
60˚
30˚
SC = 1.00 x 1.02
CERTIFIED TEST REPORT NO. 3359FR
COMPUTED BY LSI PROGRAM
**TEST-LITE**
ZONAL LUMEN SUMMARY
Zone Lumens
0-10 68.88
10-20 192.34
20-30 245.08
30-40 221.66
40-50 168.88
50-60 90.1
60-70 14.8
70-80 3.09
80-90 2.18
90-100 0
100-110 0
110-120 0
120-130 0
130-140 0
140-150 0
150-160 0
160-170 0
170-180 0
CANDLEPOWER SUMMARY
Angle 0˚ CP 90˚ CP
0 715 715
5 712 730
10 694 742
15 652 701
20 598 631
25 520 544
30 440 437
35 365 330
40 299 244
45 242 198
50 185 159
55 105 94
60 42 41
65 9 9
70 3 4
75 3 3
80 2 2
85 2 2
90 2 2
181
363
544
725
0
143
287
430
573
60˚
30˚
SC = 1.2
CERTIFIED TEST REPORT NO. 3351FR
COMPUTED BY LSI PROGRAM
**TEST-LITE**
32W TRIPLE TUBE LAMP, LUMEN RATING = 2200 LMS, ELECTRONIC BALLAST, CL FINISH TRIM WITH OPAL LENS
COEFFICIENTS OF UTILIZATION
Ceiling 80% 70% 50% 30%
Wall 70 50 30 10 50 10 50 10 50 10 0
RCR Zonal Cavity Method - Effective Floor Reflectance = 20%
Room Cavity Ratio
0 55 55 55 55 53 53 51 51 49 49 46
1 52 50 49 47 49 47 47 45 45 44 42
2 48 45 43 41 44 41 43 40 42 39 37
3 45 41 38 36 40 36 39 35 38 34 33
4 42 37 34 32 37 31 36 31 35 31 30
5 39 34 31 28 34 28 33 28 32 28 26
6 36 31 28 25 31 25 30 25 29 25 24
7 34 29 25 23 28 23 28 23 27 22 21
8 32 26 23 21 26 21 25 20 25 20 19
9 30 24 21 19 24 19 24 19 23 19 18
10 28 23 19 17 22 17 22 17 22 17 16
Determined In Accordance With Current IES Published Procedures
Luminaire Input Watts = 35.0
ZONAL LUMEN SUMMARY
Zone Lumens
0-10
54.19
10-20
153.56
20-30
223.16
30-40
245.6
40-50
211.31
50-60
105.76
60-70
13.51
70-80
2.57
80-90
2.22
90-100 0
100-110 0
110-120 0
120-130 0
130-140 0
140-150 0
150-160 0
160-170 0
170-180 0
0-30 506.3 23 50.3
0-40 727.96 33.1 72.3
0-60 986.94 44.9 98
0-90 1007.01 45.8 100
90-120 0 0 0
90-150 0 0 0
90-180 0 0 0
0-180 1007.01 45.8 100
ZONAL LUMENS AND PERCENTAGES
Zone Lumens %Lamp %Fixt
**
Efficiency = 45.8%
**
0-30 430.92 19.6 42.6
0-40 676.51 30.8 66.9
0-60 993.57 45.2 98.2
0-90 1011.87 46 100
90-120 0 0 0
90-150 0 0 0
90-180 0 0 0
0-180 1011.87 46 100
ZONAL LUMENS AND PERCENTAGES
Zone Lumens %Lamp %Fixt
**
Efficiency = 46%
**
CANDLEPOWER SUMMARY
Angle 0˚ CP
0 573
5 571
10 564
15 549
20 524
25 491
30 448
35 398
40 339
45 278
50 210
55 113
60 39
65 8
70 3
75 2
80 2
85 2
90 2