Lightolier 1004ICVN Indoor Furnishings User Manual


 
INSTRUCTION SHEET NO.
IS:1004ICV
B1204 Page 3 of 4
READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE INSTALLING FIXTURE
This fixture is intended for installation in accordance with the National Electrical Code and local regulations.
To assure full compliance with local codes and regulations, check with your local electrical inspector before
installation. To prevent electrical shock, turn off electricity at fuse box before proceeding.
Retain these instructions for maintenance reference.
®
LIGHTOLIER a GENLYTE company.
631 Airport Road, Fall River, MA 02720
8. LAMPING (Fig. H)
1. Make sure that power is OFF when lamping or relamping.
Remove LAMP RING from TRIM by pulling straight down.
2. Remove LAMP SHIELD from LAMP RING.
3. Place LAMP SHIELD on back of LAMP (MR-16) and insert both
between LAMP SPRINGS until face of lamp sits firmly on GLASS LAMP
GUARD (Fig. J).
WARNING: RISK OF FIRE. LAMP SHIELD MUST BE INSTALLED.
4. Attach SOCKET to bi-pin prongs on LAMP.
5. Insert LAMP RING with LAMP SHIELD, LAMP and GLASS LAMP
GUARD back into TRIM.
FEMALE CONNECTORS
(ATTACHED TO FIXTURE WIRES)
MALE CONNECTORS
(ATTACHED TO SOCKET WIRES)
MR16 SOCKET
LAMP SPRING
Fig. H
LAMP SHIELD
INSULATING SLEEVING
GLASS LAMP GUARD
SOCKET
LAMP RING
Fig. J
NOTE: 1. LOW VOLTAGE FIXTURES should be
dimmed only with special dimmers intended
specifically for that purpose. Use Lightolier
Lytemode, Scenist, Crescendo VA, Neptune VA,
Precision VA, Easyset VA, Sunrise VA, Radiant
VA or equivalent products by others or variable
autotransformers or electronic dimmers
intended for use with low voltage fixtures.
2. Low voltage fixtures may produce audible
sound which may be objectionable in acousti-
cally critical areas.
LAMP
WARNING: 1. LAMP MANUFACTURERS REQUIRE THE GLASS LAMPGUARD BE IN PLACE BEFORE ENERGIZING LAMP, AND THAT GREAT
CARE MUST BE TAKEN THAT LAMP IS FULLY COOLED BEFORE RELAMPING. AVOID FINGER MARKS ON INSIDE OF LAMP FOR THEY MAY
CAUSE SHORT LAMP LIFE AND POSSIBLE BREAKAGE. 2. USE ONLY REFLECTOR TRIMS
PROVIDED BY LIGHTOLIER INC. USE OF OTHER
MANUFACTURER'S REFLECTOR TRIMS VOIDS THE UNDERWRITERS LABORATORIES
LISTING AND COULD CONSTITUTE A FIRE HAZARD.