1. CUT OPENING (FIG. A)
Use MOUNTING FRAME opening as template.
2. WIRE-IN (FIG. B)
Wire to supply leads. (For Cable, use built-in Cable Clamp
in J-Box.)
3. PUT THROUGH (FIG. C)
a. Remove ADJUSTABLE MOUNTING BARS.
b. Break off BRIDGE on MOUNTING FRAME as shown in
FIG. G by breaking WEBS on SLOTS with cutting plier.
c. Pass MOUNTING FRAME into ceiling as shown.
4. ANCHOR (FIG. D)
Use ANCHOR CLIPS (order separately Catalog No. 1985N
for 1002 Frame-In Kit; Catalog No. 1985S for 1102 Frame-In
Kit). Slide ANCHOR CLIP into SLOT underneath the ROTO
CLIP (see Fig. H). Hold down MOUNTING FRAME tight
against the ceiling, push the NAIL portion of ANCHOR CLIP
into ceiling (Fig. 1). Use small nail through NAIL HOLE to
secure ANCHOR CLIP to ceiling if desired. Install all (4)
ANCHOR CLIPS.
5. SNAP-ON (FIG. E)
6. PUSH-UP (FIG. F)
INSTRUCTION SHEET NO.
IS:1102
B0203 Page 2 of 2
READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE INSTALLING FIXTURE.
This fixture is intended for installation in accordance with the National Electrical Code and local or Federal
code specifications. To assure full compliance with codes and regulations, check with your local electrical
inspector before installation. To prevent electrical shock, turn off electricity at fuse box before proceeding.
Retain these instructions for maintenance reference.
®
LIGHTOLIER a GENLYTE THOMAS company.
631 Airport Road, Fall River, MA 02720
See separate Instruction Sheet
for your choice of reflector trim.
WARNING USE ONLY REFLECTOR TRIMS PROVIDED BY LIGHTOLIER INC. USE OF OTHER MANUFACTURER REFLECTOR
TRIMS VOIDS THE UNDERWRITERS LABORATORIES LISTING AND COULD CONSTITUTE A FIRE HAZARD.