Lightolier 1001HSW Indoor Furnishings User Manual


 
Performance Recessed CFL Downlighting 10 01HSW
Page 2 of 2 5" Aperture Horizontal Wall Wash, Compact Fluor., Performance Series, Reflector Trim
Job Information Type:
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2008 Philips Group • C0808
Lightolier is a Philips group brand
2' From Wall-3' On Center2' From Wall-2' On Center2' From Wall-2' On Center
26 Watt Triple Tube Lamp 13 Watt Quad Tube Lamp
Lighting Data
Footcandles On Wall: Multiple Units
3'
2'
23 f.c.
21 f.c.
3'
2' From Wall-3' On Center
EXAMPLE:
26w
with multiple clear reflector units located 2' from wall and
spaced 3' on center, the illumination on the wall 3' down from ceiling
will be 23 f.c. beneath units and 21 f.c. between units.
Distance From Ceiling in Feet
Distance From Ceiling in Feet
Distance From Ceiling in Feet
Distance From Ceiling in Feet
23 f.c.
2'
3'
2'
3'
1' 29 27 29
2' 43 43 43
3' 33 33 33
4' 24 25 24
5' 17 18 17
6' 12 13 12
7' 9 9 9
8' 7 7 7
9' 5 5 5
1' 23 16 23
2' 27 29 27
3' 23 21 23
4' 17 17 17
5' 12 12 12
6' 9 9 9
7' 7 7 7
8' 5 5 5
9' 4 4 4
1' 13 12 13
2' 19 19 19
3' 16 16 16
4' 12 12 12
5' 8 8 8
6' 6 6 6
7' 4 4 4
8' 3 3 3
9' 2 2 2
1' 11 7 11
2' 12 13 12
3' 11 11 11
4' 8 8 8
5' 6 6 6
6' 4 4 4
7' 3 3 3
8' 2 2 2
9' 1 1 1
18 Watt Triple Tube Lamp
2' From Wall-3' On Center2' From Wall-2' On Center
Footcandle values are initial, rounded off and based on minimum of six units.
Distance From Ceiling in Feet
Distance From Ceiling in Feet
2'
3'
1' 27 26 27
2’ 41 42 41
3' 32 33 32
4' 23 23 23
5' 16 17 16
6' 11 12 11
7' 8 8 8
8' 6 6 6
9' 5 5 5
1' 22 16 22
2' 26 27 26
3' 22 21 22
4' 16 16 16
5' 12 12 12
6' 9 9 9
7' 7 7 7
8' 5 5 5
9' 4 4 4