Lightolier 1001HL Indoor Furnishings User Manual


 
Performance Recessed CFL Downlighting 1 0 0 1 H L
Page 2 of 2 5" Aperture Horizontal Wet Location, Compact Fluor., Performance Series, Reflector Trim
Job Information Type:
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2008 Philips Group • E0808
Lightolier is a Philips group brand
26W TRIPLE TUBE LAMP, LUMEN RATING = 1710 LMS, ELECTRONIC BALLAST, CL FINISH TRIM WITH CLEAR LENS
SC = 1.1
CERTIFIED TEST REPORT NO. 3345FR
COMPUTED BY LSI PROGRAM
**TEST-LITE**
150
300
450
600
60˚
30˚
26W TRIPLE TUBE LAMP, LUMEN RATING = 1710 LMS, ELECTRONIC BALLAST, CL FINISH TRIM WITH OPAL LENS
COEFFICIENTS OF UTILIZATION
Ceiling 80% 70% 50% 30% 0
Wall 70 50 30 10 50 10 50 10 50 10 0
RCR Zonal Cavity Method - Effective Floor Reflectance = 20%
Room Cavity Ratio
0 51 51 51 51 50 50 48 48 46 46 43
1 48 47 45 44 46 44 44 42 42 41 39
2 45 43 41 39 42 38 40 38 39 37 35
3 42 39 36 34 38 34 37 34 36 33 32
4 39 36 33 31 35 30 34 30 33 30 29
5 37 33 30 27 32 27 31 27 31 27 26
6 35 30 27 25 30 25 29 25 28 24 23
7 32 28 25 23 27 23 27 22 26 22 21
8 31 26 23 21 25 21 25 20 24 20 20
9 29 24 21 19 24 19 23 19 23 19 18
10 27 22 19 18 22 19 22 17 21 17 17
Determined In Accordance With Current IES Published Procedures
Luminaire Input Watts = 33.0
ZONAL LUMEN SUMMARY
Zone Lumens
0-10 47.19
10-20 133.79
20-30 178.34
30-40 167.29
40-50 137.02
50-60 60.2
60-70 6.14
70-80 1.07
80-90 .34
90-100 0
100-110 0
110-120 0
120-130 0
130-140 0
140-150 0
150-160 0
160-170 0
170-180 0
COEFFICIENTS OF UTILIZATION
Ceiling 80% 70% 50% 30% 0
Wall 70 50 30 10 50 10 50 10 50 10 0
RCR Zonal Cavity Method - Effective Floor Reflectance = 20%
Room Cavity Ratio
0 48 48 48 48 47 47 45 45 43 43 40
1 45 44 43 42 43 41 42 40 40 39 37
2 43 40 38 37 40 36 38 36 37 35 33
3 40 37 34 33 36 32 35 32 34 31 30
4 37 34 31 29 33 31 32 29 31 28 27
5 35 31 28 26 31 26 30 29 27 26 25
6 33 29 26 24 32 24 28 23 27 23 22
7 31 26 24 22 26 22 26 21 25 21 21
8 29 25 22 20 24 20 24 20 23 20 19
9 27 23 20 18 23 18 22 18 22 18 17
10 26 21 19 17 21 17 21 17 21 17 16
Determined In Accordance With Current IES Published Procedures
Luminaire Input Watts = 33.0
26W TRIPLE TUBE LAMP, LUMEN RATING = 1710 LMS, ELECTRONIC BALLAST, CL FINISH TRIM WITH FRESNEL LENS
ZONAL LUMEN SUMMARY
Zone Lumens
0-10 51.18
10-20 133.02
20-30 167
30-40 150.81
40-50 17.04
50-60 60.58
60-70 8.93
70-80 1.06
80-90 .14
90-100 0
100-110 0
110-120 0
120-130 0
130-140 0
140-150 0
150-160 0
160-170 0
170-180 0
150
300
450
600
150
300
450
600
60˚
30˚
SC = 0.92
CERTIFIED TEST REPORT NO. 3344FR
COMPUTED BY LSI PROGRAM
**TEST-LITE**
COEFFICIENTS OF UTILIZATION
Ceiling 80% 70% 50% 30% 0
Wall 70 50 30 10 50 10 50 10 50 10 0
RCR Zonal Cavity Method - Effective Floor Reflectance = 20%
Room Cavity Ratio
0 44 44 44 44 43 43 41 41 39 39 37
1 41 40 39 38 39 37 38 36 36 35 33
2 38 36 34 33 36 33 34 32 33 31 30
3 36 33 31 29 32 29 31 28 30 28 27
4 33 30 27 26 30 25 29 25 28 25 24
5 31 27 25 23 27 23 26 22 26 22 21
6 29 25 22 20 25 20 24 20 24 20 19
7 27 23 20 18 23 18 22 18 22 18 17
8 25 21 19 17 21 17 21 17 20 17 16
9 24 20 17 15 19 15 19 15 19 15 14
10 23 18 16 14 18 14 18 14 17 14 13
Determined In Accordance With Current IES Published Procedures
Luminaire Input Watts = 33.0
ZONAL LUMENS AND PERCENTAGES
Zone Lumens %Lamp %Fixt
**
Efficiency = 36.6%
**
0-30 275.21 16.1 44
0-40 428.79 25.1 68.5
0-60 618.1 36.1 98.7
0-90 626.05 36.6 100
90-120 0 0 0
90-130 0 0 0
90-150 0 0 0
90-180 0 0 0
0-180 626.05 36.6 100
ZONAL LUMEN SUMMARY
Zone Lumens
0-10
34.84
10-20
98.51
20-30
141.87
30-40
153.58
40-50
129
50-60
60.3
60-70
7.52
70-80
.43
80-90
0
90-100
0
100-110
0
110-120
0
120-130
0
130-140
0
140-150
0
150-160
0
160-170
0
170-180
0
CANDLEPOWER SUMMARY
Angle 0° CP 90° CP
0
369 369
5
365 368
10
360 362
15
349 351
20
332 334
25
309 310
30
280 281
35
247 248
40
208 208
45
168 167
50
124 123
55
62 62
60
22 24
65
4 5
70
1 1
75
1 0
80
0 0
85
0 0
90
0 0
150
300
450
600
100
200
300
400
60˚
30˚
SC = 1.1
CERTIFIED TEST REPORT NO. 3346FR
COMPUTED BY LSI PROGRAM
**TEST-LITE**
1
1
1
CANDLEPOWER SUMMARY
Angle 0° CP
0 486
5 486
10 476
15 457
20 427
25 373
30 312
35 262
40 231
45 208
50 122
55 66
60 19
65 4
70 2
75 1
80 1
85 0
90 0
CANDLEPOWER SUMMARY
Angle 0° CP
0 562
5 545
10 514
15 477
20 423
25 362
30 302
35 248
40 203
45 165
50 125
55 68
60 27
65 6
70 1
75 1
80 1
85 0
90 0