Lightolier 1001 Indoor Furnishings User Manual


 
Lytecaster
®
Performance IC Downlighting 1001
Page 2 of 2 5" Aperture Vertical Open, Compact Fluorescent, Performance Series, Reflector Trim
Job Information Type:
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2008 Philips Group • B0808
Lightolier is a Philips group brand
26W TRIPLE TUBE LAMP, LUMEN RATING = 1710 LMS, ELECTRONIC BALLAST, CL FINISH TRIM
181
363
544
725
1
150
300
450
600
60˚
30˚
18W TRIPLE TUBE LAMP, LUMEN RATING = 1200 LMS, ELECTRONIC BALLAST, CL FINISH TRIM
125
250
375
500
60˚
30˚
COEFFICIENTS OF UTILIZATION
Ceiling 80% 70% 50% 30%
Wall 70 50 30 10 50 10 50 10 50 10 0
RCR Zonal Cavity Method - Effective Floor Reflectance = 20%
Room Cavity Ratio
0 64 64 64 64 63 63 60 60 57 57 54
1 60 59 57 59 58 55 55 53 53 52 49
2 57 54 51 49 53 48 51 47 49 46 44
3 53 49 46 43 48 43 47 42 45 41 40
4 49 45 38 44 38 43 37 42 37 36 41
5 46 41 37 34 40 34 39 34 38 33 32
6 43 37 33 31 37 31 36 30 35 30 29
7 40 34 30 28 34 28 33 27 33 27 26
8 38 32 28 25 31 25 31 25 30 25 24
36 36 29 26 23 29 23 28 23 28 23 22
10 33 27 24 21 27 21 27 21 26 21 20
Determined In Accordance With Current IES Published Procedures
Luminaire Input Watts = 27.0
ZONAL LUMENS AND PERCENTAGES
Zone Lumens %Lamp %Fixt
0-30 415.94 24.3 45.2
0-40 659.16 38.5 71.7
0-60 918.96 53.7 99.9
0-90 919.93 53.8 100
90-120 0 0 0
90-130 0 0 0
90-150 0 0 0
90-180 0 0 0
0-180 919.93 53.8 100
**
Efficiency = 53.8%
**
ZONAL LUMEN SUMMARY
Zone Lumens
0-10
47.69
10-20
143.32
20-30
224.93
30-40
243.22
40-50
196.58
50-60
63.22
60-70
.97
70-80
0
80-90
0
90-100
0
100-110
0
110-120
0
120-130
0
130-140
0
140-150
0
150-160
0
160-170
0
170-180
0
CANDLEPOWER SUMMARY
Angle 0˚ CP
0 481
5 496
10 507
15 500
20 512
25 492
30 449
35 392
40 324
45 258
50 178
55 56
60 4
65 1
70 1
75 0
80 0
85
0
90
0
SC = 1.3
CERTIFIED TEST REPORT NO. 3067FR
COMPUTED BY LSI PROGRAM
**TEST-LITE**
COEFFICIENTS OF UTILIZATION
Ceiling 80% 70% 50% 30%
Wall 70 50 30 10 50 10 50 10 50 10 0
RCR Zonal Cavity Method - Effective Floor Reflectance = 20%
Room Cavity Ratio
0 71 71 71 71 69 69 66 66 64 64 60
1 67 65 64 62 64 61 62 59 59 57 55
2 63 60 57 54 59 54 57 53 55 51 49
3 59 55 51 48 54 48 52 47 50 46 44
4 55 50 46 43 49 43 48 42 47 42 40
5 52 46 42 38 45 38 44 38 43 38 36
6 48 42 38 35 41 35 40 34 40 34 33
7 45 39 34 31 34 31 37 31 37 31 30
8 42 36 31 29 35 29 35 28 34 28 27
36 40 33 29 26 33 26 32 26 32 26 25
10 38 31 27 24 31 24 30 24 29 24 23
Determined In Accordance With Current IES Published Procedures
Luminaire Input Watts = 22.0
ZONAL LUMENS AND PERCENTAGES
Zone Lumens %Lamp %Fixt
0-30 338.39 28.2 47.2
0-40 529.08 44.1 73.8
0-60 715.78 59.6 99.8
0-90 716.88 59.7 100
90-120 0 0 0
90-130 0 0 0
90-150 0 0 0
90-180 0 0 0
0-180 716.88 59.7 100
**
Efficiency = 59.7%
**
ZONAL LUMEN SUMMARY
Zone Lumens
0-10 38.92
10-20 117.03
20-30 182.44
30-40 190.69
40-50 144.07
50-60 42.62
60-70 1.11
70-80 0
80-90 0
90-100 0
100-110 0
110-120 0
120-130 0
130-140 0
140-150 0
150-160 0
160-170 0
170-180 0
CANDLEPOWER SUMMARY
Angle 0˚ CP
0 393
5 405
10 413
15 409
20 418
25 399
30 361
35 307
40 249
45 192
50 114
55 40
60 3
65 1
70 0
75 0
80 0
85 0
90 0
SC = 1.3
CERTIFIED TEST REPORT NO. 3066FR
COMPUTED BY LSI PROGRAM
**TEST-LITE**