LG Electronics LW1800ERZ3 Air Conditioner User Manual


 
34 Room Air Conditioner
Troubleshooting Guide
Possible Trouble 6 Remote controller does not operate.
Possible Trouble 7 It displays abnormally on DC PCB Assy.
NO
NO
NO
NO
YES
YES
YES
Is the IC01G good?
Is the connection of
CN-AC/DC
OK?
Replace the DC
PCB Ass'y.
Replace IC01G.
Replace IC03G
(Q01G, Q02G, Q03G
for Delux Model).
Connect connector
to
CN-AC/DC
exactly.
Does the IC03G
(Q01G, Q02G, Q03G for Delux Model)
operate normally on DC
PCB Ass'y?
Is the voltage of Battery
over 2.3V?
Replace Receiver Ass'y.
Is the connection of
CN-AC/DC
OK?
Is the voltage No.10
of CN-AC/DC on DC PCB
Ass'y DC 5V?
Replace the battery.
Connect connector to
CN-AC/DC
exactly.
NO
NO
NO
YES
YES
YES
Check the PCB pattern.