- 2 -
Copyright ©2008 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
1. Specification
Cooling Capacity kW
Btu/h.
Heating Capacity ( for Heat Pump models) kW
Btu/h.
Electric Heater capacity kW
Btu/h.
Power Input Cooling/Heating W
Running Current Cooling/Heating A
Starting current Cooling/Heating A
Electric Heater Current A
EER W/W
Btu/h.W
COP W/W
Power Supply Ø / V / Hz
Power Factor %
MCA A
MOP A
Air Flow Rate Indoor,Max m
3
/min(CFM)
Outdoor,Max m
3
/min(CFM)
Moisture Removal l/h
Sound Level Indoor,H/M/L dB(A)±3
(SoundPressure,1m) Outdoor,Max dB(A)±3
Refrigerant & Charge g(oz)
Compressor Type
Model
Motor Type
Oil Type
Oil Charge cc
O.L.P Name
Fan Type(In/Out)
Motor Type(In/Out)
Motor Output(In/Out) W
Power Supply Cable (Power Cord) No.*mm
2
Dimensions ( W * H * D) mm
inch
Net Weight kg(lbs)
Tool Code(Chassis)
Features Temperature Control
Energy Saver Mode
Prefilter(washable/anti-fungus)
Plasma Filter
Steps, Fan/Cool/Heat
Airflow Direction Control(up&down)
Airflow Direction Control(left&right)
Remote Controller Type
Setting Temperature Range Cooling
Heating
Auto Operation (Micom Control)
Panel Touch Type
Timer
Air Discharge
Air-Ventilation
Defrost Control
Hot Start
Look
Cabinet Type(Chassis Type)
Special Function
Model
LP091HEM-Y8
2.49 2.54
8500 8700
2.14 2.20
7300 7500
3.08 3.49
10500 11900
787/676 805/694
3.95/3.4 3.65/3.15
--
14.9 15.2
3.17 3.17
10.8 10.8
3.17 3.17
1 / 208 / 60 1 / 230 / 60
95.8/95.6 95.9/95.8
19.2
20.0
8.5(300)
-
1.2
45/-/43
60
R22, 585(20.6)
Rotary(Non Tropical)
QA114KCB
PSC
SUNISO 4GSI
290
MRA12017 - 12026
Cross Flow Fan Axial Fan
4 Poles
10.1/44
3 * 2.1
1066*406*505
42*16*19-7/8
38.5 (84.8)
YA
Thermistor
O
O
-
2/2/2
Manual
-
Wall Thermostat
54°F ~ 86°F(12.2°C ~ 30°C)
54°F ~ 86°F(12.2°C ~ 30°C)
-
Mechanical Controls
-
Rear
O
O
-
L - Look
Slide In-Out
Electric Heater
Note:
O
: Applied, - : No relation
*
For circuit breaker rating, please confirm to local standards wherever necessary.
❈
Some of functions are slightly different depending upon models.
❈
The specification may be subject to change without prior notice for purpose of improvement.