LG Electronics LP091CEM-Y8 Air Conditioner User Manual


 
- 29 -
Copyright ©2008 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
4. Secure the grille to the sleeve by tightening the four screws
to their corresponding holes in the grille.
5. Remove the wire handle after the installation is complete.
Note:
The stamped aluminum grille includes 6 screws, washers,
nuts, and plastic grommets. The architectural grille includes 4
screws.
Condensate Drain kit
Part No: AYDR101
Description
Condensate water will drain from the chassis into the sleeve
during normal heat pump operation. This can also occur
during times of high humidity when in cooling operation.
Install either the outdoor or indoor drain kit components to
control the condensate water where normal drainage from the
wall sleeve is not possible or undesirable. See Figure 35 for
all components of the drain kit.
WARNING
Hazardous Voltage!
Disconnect all electric power, including remote disconnects
before servicing. Follow proper lockout/ tagout procedures to
ensure the power can not be inadvertently energized. Failure
to disconnect power before servicing could result in death or
serious injury.
Important Note:
The unit OFF switch does not disconnect all electrical power
to this unit.
Receiving
Upon receipt of the product, inspect the shipping carton for
signs of visible damage. Report any damage or shortage to
the carrier and note it on the delivery receipt. The product
must be stored in its original shipping carton in a dry, secure
place prior to its installation and use.
Installation
The installation and servicing of the equipment referred to in
this booklet should be performed by qualified, experienced
technicians.
Drain Installation
Note:
The optional drain kit serves only as a link between the unit
and field-supplied condensate drain system.
Installing the kit without connecting it to a drainage system
will result in inadequate condensate removal, possible
leakage and corrosion.
Algaecide: Some algaecide products may cause damage to
the unit basepan and therefore should not be used. Contact
your sales representative when considering the use of a
commercial algaecide. See Figure 41 for components of the
drain kit.
DRAIN FITTING
PLATE B
BLANK-OFF
PLATE C
BLANK-OFF
PLATE C
GASKETS A
1/2" DRAIN FITTING
MTG. SCREWS
MTG. SCREWS
BLANK-OFF
PLATE D
GASKET E FOR
PLATE D
Figure 41 Components of Drain Kits