LG Electronics LA090HPI Air Conditioner User Manual


 
22
Zone
Flex Multi Split
Indoor Units
Outdoor Units
Model
LMI090CP
LMA090CP
LMI120CP
LMA120CP
LMA121CPM
LMI090HP
LMA090HP
LMI120HP
LMA120HP
LMA121HPM
LMO240C
LMO360C
LMO240H
LMO360H
Indoor
36V DC
36V DC
36V DC
36V DC
36V DC
36V DC
36V DC
36V DC
36V DC
36V DC
BTUs
9,000
9,000
12,000
12,000
12,000
9,000
9,000
12,000
12,000
12,000
24,000
36,000
24,000
36,000
Electrical Specifications
Outdoor
230/208
230/208
230/208
230/208
Voltage
*Minimum Circuit Ampacity
**Maximum Overcurrent Protection
Wire Size
Minimum AWG 14-3
Indoor/Outdoor Connecting Cable Shielded 18-4
Flex Multi Split
Type
A/C
A/C
A/C
A/C
A/C
H/P
H/P
H/P
H/P
H/P
Model
LMI090CP
LMA090CP
LMI120CP
LMA120CP
LMA121CPM
LMI090HP
LMA090HP
LMI120HP
LMA120HP
LMA121HPM
Pipe size
Liquid Suction
1/4"
1/4"
1/4"
1/4"
1/4"
1/4"
1/4"
1/4"
1/4"
1/4"
BTUs
9,000
9,000
12,000
12,000
12,000
9,000
9,000
12,000
12,000
12,000
Additional
Refrigerant
0.21 oz./ft.
0.21 oz./ft.
0.21 oz./ft.
0.21 oz./ft.
0.21 oz./ft.
0.21 oz./ft.
0.21 oz./ft.
0.21 oz./ft.
0.21 oz./ft.
0.21 oz./ft.
Max. length
each pipe
50'
50'
50'
50'
50'
50'
50'
50'
50'
50'
Max.
elevation
25'
25'
25'
25'
25'
25'
25'
25'
25'
25'
Refrigerant Line & Formula Specifications***
25' maximum
8' minimum
12' maximum
OIL TRAP
INDOOR UNIT
OUTDOOR UNIT
3/8"
3/8"
3/8"
3/8"
3/8"
3/8 "
3/8"
3/8"
3/8"
3/8"
HIGH WALL DUCT LESS • FLEX MULTI SPLIT • DUAL & TRI ZONE
ELECTRICAL & REFRIGERATION QUICK REFERENCE
NOTE: Recommend shielded cable for low voltage wiring.
Please see local electrical codes for proper wire specifications.
All equipment single phase.
Type
A/C
A/C
A/C
A/C
A/C
H/P
H/P
H/P
H/P
H/P
A/C
A/C
H/P
H/P
Rated
Amps
0.5
1.3
0.5
1.3
0.5
0.5
1.3
0.5
1.3
0.5
11.1
16.6
11.1
16.6
MCA*
20
20
20
20
MOP**
20
30
20
30
***Dual Zone: exterior unit has sufficient refrigerant for charging two indoor coils and a 25 ft. line set per indoor unit.
Tri Zone: exterior unit has sufficient refrigerant for charging three indoor coils and a 25 ft. line set per indoor unit.
NOTE: Systems having the outdoor unit mounted above the indoor unit (e.g. basement installations) have the
following additional requirement:
For systems with maximum elevation of 25 ft. (see Figure A), refrigerant lines must be oil
trapped between 8 ft. and 12 ft. of elevation.
For systems with elevation of greater than 25 ft. Refrigerant lines must be oil trapped at least every 12 ft.
of elevation.
* Each system should have a 6-8 inch inverted trap at the condensing unit if mounted above indoor unit.
Figure A.
Example: 25 ft. maximum elevation.