LG Electronics LA090CP Air Conditioner User Manual


 
28
Floor Standing
Ceiling Cassette
Type
A/C
A/C
A/C
A/C
System #
LF300CP
LF480CE
LC240CP
LC340CP
Indoor
230/208
230/208
230/208
230/208
BTUs
28,000
48,000
24,000
34,000
Rated
Amps
11.5/11.5
20.0/20.0
11.5/12.4
15.1/16.5
MCA*
17***
28.9***
17.3
27.5
MOP**
25***
50***
30
50
Electrical Specifications
Outdoor
230/208
230/208
230/208
230/208
Voltage
All equipment single phase.
NOTE: Please see local electrical codes for proper wire specifications.
*Minimum Circuit Ampacity
**Maximum Overcurrent Protection
***Floor standing MCA + MOP calculated for indoor and outdoor
units connected to common breaker (Preferred method).
Wire Size
Minimum AWG 14-3
Indoor/Outdoor Connecting Cable Minimum AWG 14-3
Floor Standing
Ceiling Cassette
Type
A/C
A/C
A/C
A/C
System #
LF300CP
LF480CE
LC240CP
LC340CP
Pipe size
Liquid Suction
3/8" 5/8"
3/8" 3/4"
1/4" 1/2"
1/4" 5/8"
BTUs
28,000
48,000
24,000
34,000
Additional
Refrigerant
0.32 oz./ft.
0.42 oz./ft.
0.32 oz./ft.
0.42 oz./ft.
Max. length
each pipe
100'
131'
100'
115'
Max.
elevation
66'
82'
50'
66'
Refrigerant Line Specifications
Each system is pre-charged with enough refrigerant to charge 25 ft. of line and the interior unit.
NOTE: Systems having the outdoor unit mounted above the indoor unit (e.g. basement
installations) have the following additional requirement:
For systems with maximum elevation of 25 ft. (see Figure A), refrigerant lines must be oil trapped
between 8 ft. and 12 ft. of elevation.
For systems with elevation of greater than 25 ft. Refrigerant lines must be oil trapped at least
every 12 ft. of elevation.
* Each system should have a 6-8 inch inverted trap at the condensing unit if mounted above
indoor unit.
DUCT LESS • FLOOR STANDING & CEILING CASSETTE • SINGLE ZONE
ELECTRICAL & REFRIGERATION QUICK REFERENCE
25' maximum
8' minimum
12' maximum
OIL TRAP
INDOOR UNIT
OUTDOOR UNIT
Figure A.
Example: 25 ft. maximum elevation.