LG Electronics AS-W126URH1/UBH1/UWH1/UMH1 Air Conditioner User Manual


 
30 Room Air Conditioner
Functions
Room temperature sensor. (Thermistor)
Pipe temperature sensor. (Thermistor)
Maintain the room temperature in accordance with the Setting Temp.
Indoor fan is delayed for 5 sec at the starting.
Restarting is for approx. 2 minutes.
Super High, High, Med, Low
--- Lights up in operation
--- Lights up in Sleep Mode
--- Lights up in Timer Mode
--- Lights up in Preheat Mode (for Heating Model)
--- Lights up in Plasma Air Clean Mode
Intermittent Operation of fan at low speed or off.
The fan is switched to low(Cooling), low(Heating) speed.
The unit will be stopped after 1, 2, 3, 4, 5, 6, 7 hours.
The fan is switched to intermittent or irregular operation
The fan speed is automatically switched from high to low speed.
The louver can be set at the desired position or swing
up and down automatically.
Indoor Unit
Operation ON/OFF by Remote controller
Sensing the Room Temperature
Room temperature control
Starting the Current Control
Time Delay Safety Control
Indoor Fan Speed Control
Operation indication Lamps (LED)
Soft Dry Operation Mode
Both the indoor and outdoor fan stops
during defrosting.
The indoor fan stops until the
evaporator pipe temperature will be
reached at 34°C.
Sleep Mode Auto Control
Natural Air Control by CHAOS Logic
Airflow Direction Control
PLASMA
Defrost(Deice) control (Heating)
Hot-start Control (Heating)
Heater (Optional)
The function will be operated while in any
operation mode with selecting the function.
The function is to be stopped while it is
operating with selecting the function.
PLASMA
AUTO CLEAN(Optional)
Horizontal airflow Direction Control(Optional)
Energy-Saving control(Optional)
Auto Changeover
Functions