LG Electronics AS-H096PB/D/M/WL1 Air Conditioner User Manual


 
Remove pipe cover and side cover
1. Remove two screws(for fixing pipe cover)
2. Pull up the side cover of desired connecting direction,
and then side cover is separated.
3. Pick the pipe hole of the side cover.
CAUTION: After removing the pipe
hole, cut the burr for safety.
When making pipe path through rear
wall, you dont need to pick the pipe hole.
Drain hose junction
1. Remove the rubber stopple in the desired drain direc-
tion.
2. Insert drain hose into the handle of drain pan, and
join drain hose and connecting hose according to the
figure by.
NOTICE
Open front panel
1. Push the front panel backward and lift it up to remove the two screws.
2. As soon as you lift the both lower parts of panel front, you can hear the sound from panel front. At this moment
panel front is separated
3. After pulling down this panel a bit, separate connecting wire from the product.
Service Manual 13
Installation
Panel Front
Connector
Pipe hole
Side cover
rubber cap
Only the
desired direction
Connecting
part
Adhesive
Drain
hose
Preparing Work for Installation