CONTINUOUS COMFORT
NETWORK
The G60V Variable Speed
Furnace is designed to easily
integrate with other quality Lennox
®
products, providing a total home
comfort solution:
XC21 Air Conditioner is the
most quiet and efficient central
air conditioner you can buy.***
PureAir
™
Air Purification System
cleans the air in your home better
than any other single system
you can buy.
Humiditrol
®
Whole-Home
Dehumidification System
helps reduce humid conditions
in the home.
Harmony III
™
Zoning System
provides customized, room-to-room
comfort.
** * A combination of sound ratings established
per ARI’s test standard: 270 and efficiency
ratings established per ARI’s test standard:
ANSI/ARI 210/240-2005.
G60UHV G60UHV G60UHV G60UHV G60UHV
Model 36A-070 (X) 36B-090 60C-090 (X) 60C-110 (X) 60D-135 (X)
Heating Efficiency (AFUE) 80% 80% 80% 80% 80%
Dimensions HxWxD (in.) 40 x 14-1/2 x 28-1/2 40 x 17-1/2 x 28-1/2 40 x 21 x 28-1/2 40 x 21 x 28-1/2 40 x 24-1/2 x 28-1/2
HxWxD (mm) 1016 x 368 x 724 1016 x 446 x 724 1016 x 533 x 724 1016 x 533 x 724 1016 x 622 x 724
Note: Due to Lennox’ ongoing commitment to quality, all specifications, ratings and dimensions are subject to change without notice.
Dave Lennox Signature
®
Collection G60V Specifications
Quiet Exclusive
SilentComfort
™
technology
maximizes your comfort while
minimizing sound
Since the first stage (low heat) meets
your household heating demands
approximately 80% of the time, the
G60V furnace is much quieter than
standard, single-stage furnaces.
And the variable speed motor
ramps up to speed slowly, so there’s
no sudden blast of air at startup.
A specially insulated cabinet further
reduces operating sound.
Lennox is proud of the
fact that these products
have earned the Good
Housekeeping Seal.
4
THIS MODEL
80%
Healthier Slowly
circulates air for better
indoor air quality
When you set your thermostat
to “FAN,” the G60V continues to
slowly circulate air throughout your
home. That means you can run the
fan at two-thirds less than the cost
of a traditional blower. It also
means better indoor air quality—
low-speed fan operation increases
the effectiveness of your filters,
allowing them to capture and
remove more contaminants.
SOUND INTENSITY
A traditional furnace is up to
4-1/2
times louder than the G60V.
Based on sound pressure levels during steady-state, high-fire operation of Lennox G60UHV-36A-070
and leading competitive units at mid-point temperature rise and minimum external static pressure
when set up per Section 4.5.3 of ARI 260.