4 - White Rodgers 36E/36F Gas Valve - Switch gas
valve lever to OFF.
Honeywell VR8205 Gas Valve - Turn knob on gas
valve clockwise
to OFF. Do not force.
5 - Replace the upper access panel.
Filters
All G50UHi filters are installed external to the unit. Filters
should be inspected monthly. Clean or replace the filters
when necessary to ensure proper furnace operation. ReĆ
placement filters must be rated for high velocity airflow.
Table 1 lists recommended filter sizes.
A filter must be in place whenever the unit is operating.
TABLE 1
Furnace
Filter Size
Furnace
Cabinet Size
Side Return Bottom Return
17-1/2" 16 X 25 X 1 (1) 16 X 25 X 1 (1)
21" 16 X 25 X 1 (1) 20 X 25 X 1 (1)
24-1/2" 16 X 25 X 1 (2) 24 X 25 X 1 (1)
Maintenance
A qualified service technician should inspect the complete
system each season (heating and cooling). The following
maintenance procedures should only be conducted by a
qualified service technician. Do not attempt to service
the unit in any way.
WARNING
ELECTRICAL SHOCK, FIRE,
OR EXPLOSION HAZARD.
Failure to follow safety warnings exactly could result
in dangerous operation, serious injury, death or
property damage.
Improper servicing could result in dangerous operaĆ
tion, serious injury, death, or property damage.
Before servicing, disconnect all electrical power to
furnace.
When servicing controls, label all wires prior to disĆ
connecting. Take care to reconnect wires correctly.
Verify proper operation after servicing.
Venting System
WARNING
Asphyxiation Hazard
The exhaust vent for this furnace must be securely
connected to the furnace flue collar at all times.
For your safety and to fulfill the terms of the limited
warranty, a qualified service technician must annualĆ
ly inspect this furnace and its vent system.
Annually (before heating season) inspect furnace venting
system, vent cap, heat exchanger, and burners for corroĆ
sion, deterioration, or deposits of debris. Remove any obĆ
structions.
Inspect the furnace for obvious signs of deterioration.
Inspect the furnace venting system to make sure it is in
place, physically sound, and without holes, corrosion, or
blockage.
Vent pipe must be clear and free of obstructions and must
slope upward away from the furnace.
Inspect the furnace return air duct connection to ensure
duct is sealed to the furnace and terminates outside the
space containing the furnace.
Inspect the physical support of the furnace to guarantee
that it is sound without sagging, cracks or gaps around
base and it maintains seal between base and support.
Inspect and clean the condensate trap and drain.
During a seasonal check the service technician will inspect
the indoor blower, burner flames and electrical connections
along with the venting system.
Blower
Check the blower wheel for debris and clean if necessary.
The blower motors are prelubricated for extended bearing
life. No further lubrication is needed.
WARNING
The blower access panel must be securely in place
when the blower and burners are operating. Gas
fumes, which could contain carbon monoxide, can
be drawn into living space resulting in personal injuĆ
ry or death.
Burner Flame
CAUTION
To ensure proper operation, a qualified technician
should annually check the burner flame.
Electrical
1 - Check all wiring for loose connections.
2 - Check for the correct voltage at the furnace (furnace
operating).
3 - Check amp-draw on the blower motor.
Motor Nameplate__________Actual__________