Lennox International Inc. G32V SERIES Furnace User Manual


 
Page 3
WARNING
Product contains fiberglass wool.
Disturbing the insulation in this product during
installation, maintenance, or repair will expose you
to fiberglass wool dust. Breathing this may cause
lung cancer. (Fiberglass wool is known to the State
of California to cause cancer.)
Fiberglass wool may also cause respiratory, skin,
and eye irritation.
To reduce exposure to this substance or for further
information, consult material safety data sheets
available from address shown below, or contact
your supervisor.
Lennox Industries Inc.
P.O. Box 799900
Dallas, TX 75379-9900
WARNING
Do not set thermostat below 60_F (16_C) in heating
mode. Setting thermostat below 60_F (16_C) reĆ
duces the number of heating cycles. Damage to the
unit may occur that is not covered by the warranty.
WARNING
If overheating occurs or if gas supply fails to shut
off, shut off the manual gas valve to the appliance
before shutting off electrical supply.
WARNING
Do not use this furnace if any part has been underĆ
water. Immediately call a qualified service techniĆ
cian to inspect the furnace and to replace any part
of the control system and any gas control which
has been under water.
CAUTION
Before attempting to perform any service or mainteĆ
nance, turn the electrical power to unit OFF at disĆ
connect switch.
IMPORTANT
Any additions, changes, or conversions required in
order for the appliance to satisfactorily meet the apĆ
plication needs must be made by a Lennox service
technician using factory specified and approved
parts.
Important Directions
1 - Keep the furnace area clear and free of combustible
material, gasoline, and other flammable vapors and
liquids. If installed in an insulated area, furnace must
be kept free of insulating material. Insulating material
may be combustible.
2 - DO NOT obstruct air flow to unit. Unit must receive
an unobstructed flow of combustion and ventilatĆ
ing air.
3 - DO NOT store chlorine or fluorine products near unit
or introduce these products into the combustion air.
These products can cause furnace corrosion.
4 - DO NOT draw the return air from a room where
another gas appliance (ie., a water heater) is
installed. Even though this furnace draws its comĆ
bustion air from outside of the structure, other gas
appliances that share a utility room may not. When
return air is drawn from a room, a negative pressure
is created in the room. If a gas appliance is operating
in a room with negative pressure, the flue products
can be pulled back down the vent pipe and into the
room. This reverse flow of the flue gas may result in
incomplete combustion and the formation of carbon
monoxide gas. This toxic gas might then be distribĆ
uted through the house by the furnace duct system.
Your furnace is a gas appliance. It is critical that the gas
supplied to the unit be completely burned to avoid the proĆ
duction of carbon monoxide gas. Complete combustion
of the gas requires, but is not limited to, correct gas presĆ
sure and gas flow rate, adequate combustion, air, and
proper venting.
WARNING
Carbon monoxide gas is invisible, odorless, and
toxic.
Exposure to this gas can cause personal injury and even
death to all occupants, including pets. Any item that is
powered by or gives off heat from a combustion process
(including lawn mowers, automobiles, and fireplaces) has
the potential to produce carbon monoxide gas. Because
of this, Lennox recommends the use of a carbon monĆ
oxide detector in your home, even if you do not own
gas appliances. Reliable detectors are available at reaĆ
sonable retail prices. Contact your independent Lennox
dealer for more details about this investment in your safety.
Your furnace is designed to meet standards set by nationĆ
al agencies, and to operate safely when properly installed
and maintained. However, the unit's performance can be