Use only your hand to push in or move the gas control
lever or switch. Never use tools. If the lever or switch
will not push in or move by hand, do not try to repair it,
call a qualified service technician. Force or attempted
repair may result in a fire or explosion.
Important Directions
1. Keep the furnace area clear and free of combustible
material, gasoline, and other flammable vapors and
liquids. If installed in an insulated area, furnace must
be kept free of insulating material. Insulating material
may be combustible.
2. DO NOT obstruct air flow to unit. Unit must receive
an unobstructed flow of combustion and ventilatĆ
ing air.
3. DO NOT store chlorine or fluorine products near unit
or introduce these products into the combustion air.
These products can cause furnace corrosion.
4 - DO NOT draw the return air from a room where
another gas appliance (ie., a water heater) is
installed. Even though this furnace draws its comĆ
bustion air from outside of the structure, other gas
appliances that share a utility room may not. When
return air is drawn from a room, a negative pressure
is created in the room. If a gas appliance is operating
in a room with negative pressure, the flue products
can be pulled back down the vent pipe and into the
room. This reverse flow of the flue gas may result in
incomplete combustion and the formation of carbon
monoxide gas. This toxic gas might then be distribĆ
uted through the house by the furnace duct system.
Your furnace is a gas appliance. It is critical that the gas
supplied to the unit be completely burned to avoid the proĆ
duction of carbon monoxide gas. Complete combustion
of the gas requires, but is not limited to, correct gas presĆ
sure and gas flow rate, adequate combustion, air, and
proper venting.
WARNING
Carbon monoxide gas is invisible, odorless, and
toxic
Exposure to this gas can cause personal injury and even
death to all occupants, including pets. Any item that is
powered by or gives off heat from a combustion process
(including lawn mowers, automobiles, and fireplaces) has
the potential to produce carbon monoxide gas. Because
of this, Lennox recommends the use of a carbon monĆ
oxide detector in your home, even if you do not own
gas appliances. Reliable detectors are available at reaĆ
sonable retail prices.
Contact your independent Lennox dealer for more details
about this investment in your safety.
Your furnace is designed to meet standards set by nationĆ
al agencies, and to operate safely when properly installed
and maintained. However, the unit's performance can be
greatly impacted by the individual installation and the opĆ
erating environment. It is your responsibility to ensure
that this appliance is maintained. Proper maintenance is
critical for your safety and the satisfactory operation of the
product. Lennox strongly recommends annual inĆ
spection and maintenance of this appliance. Contact
your independent Lennox dealer for an inspection by a
qualified service technician.
Unit Operation
This appliance does not have a pilot. It is equipped
with an ignition system which automatically lights
the burner. Do not try to light by hand.
A-Gas Valve Operation
WARNING
If you do not follow these instructions exactly, a fire
or explosion may result causing property damage,
personal injury or death.
Gas Valve Operation for Robertshaw and White
Rodgers Valves (Figures 2 and 4)
FIGURE 2
ROBERTSHAW 7200 GAS VALVE
GAS VALVE
SELECTOR ARM
IN OFF
POSITION
WHITE RODGERS
36E GAS VALVE
GAS VALVE
SHOWN
IN OFF
POSITION