INSTALLER settings (continued)
ENERGY EFFICIENT RECOVERY
When turned on, the thermostat will look up to two hours before the next event and anticipate when
to turn on to reach the desired temperature.
NOTE: This will not allow the second stage to turn on until 20 minutes before the event.
DEADBAND SETPOINT
Deadband is used only when the AUTO CHANGEOVER feature is enabled. The deadband is the
temperature difference between the heating and cooling setpoints. This is adjustable from 3-8°F
(2.0-4°C).
HUMIDITROL
If the HUMIDITROL accessory is present in the HVAC equipment, this feature should be enabled.
Otherwise, it should be disabled.
SECURITY CODE
Enter a code to prevent changes to the INSTALLER settings.
23
USER MENU
SELECT
ENTER SECURITY CODE
FOR INSTALLER
SETTINGS
0 0 0 0
USER MENU
SELECT
ENERGY EFFICIENT
RECOVERY
DISABLE
ENABLE
USER MENU
SELECT
DEADBAND SETPOINT
3 ˚F
INSTALL MENU
SELECT
HUMIDITROL
DISABLE
ENABLE