Lennox Hearth RDV33/40 Indoor Fireplace User Manual


 
8
Features
Installation Options
.25Manufactured (Mobile) Home
Natural Gas Or Propane (LP)
Bedrooms
Optional Wall-mounted Or Remote Thermostat
Electrical
The standard blower motor requires 120 Volts AC for operation. The
fireplace is not dependent on the blower or an outside electrical supply to
operate. WARNING - Electrical Grounding Instructions - This appliance
is equipped with a three-prong (grounding) plug for your protection
against shock hazard and should be plugged directly into a properly
grounded three-prong receptacle. Do not cut or remove the grounding
prong from this plug.
Millivolt Valve
This appliance is operated with a millivolt valve and therefore burns even
during a power outage.
Fuel
This appliance comes from the factory equipped to burn natural gas at
a specified elevation. The appliance can be converted to burn LP (liquid
propane) by installing a conversion kit. Only Lennox Hearth Products
conversion kits can be used to convert from NG to LP or LP to NG.
Contact your Lennox Hearth Products dealer for details.
Packaging List
To install your appliance, an insert body, face, surround (flange) kit and
a set of brick panels are required.
Insert Body Packaging List
1 Insert Body with Burner Cassette
1 Set of Refractory Brick Panels
1 Log Set
1 Bag of Embers
1 Fasteners: 6 slotted 1/4" truss screws
6 speed nuts
9 spring clips
3 plastic adhesive wire restraints
1 Installation and Operation Manual
Decorative Faces - One Required
Traditional Arch inset
Foundry™ Screen
Cast pillar
Surround Kits - One Required
Traditional 1-pc. (41"W x 29"H)
Traditional 3-pc.(41"W x 29"H, 48"W x 29"H, 41"W x
33"H or 48"W x 33"H)
Cast Iron (45-1/2"W x 30"H-Cast Pillar face only) *
* See detailed dimensions on Page 27.
Surround Kit Contents
1 Top Surround
2 Side Surrounds
3 Black Extruded Trim Pieces
2 Elbowed Trim Fasteners
PRE-INSTALLATION
RATINGS RDV40 / SDVI40 RDV33 / SDVI33
NATURAL GAS LP GAS NATURAL GAS LP GAS
Max/Min Input BTUh 0-2,000 Feet
(0-610 M)
u
40,000/28,000 37,500/26,000 33,000/24,000 33,000/24,000
Manifold Pressure (IN. WC) 3.5 10.0 3.5 10.0
Min. Inlet Pressure (IN. WC) 5.0 10.5 5.0 10.5
Maximum heat output BTUs/hour-
steady state (depending on vent con-
figuration)
v
83% 83% 83% 83%
P4 Efficiency
w
67.17% 69.07% 65.55% 67.80%
Orifice (DMS) 0-2,000 Feet (0-610 M)
u
1/8” #49 #36 #51
uUnit factory equipped for 0-2000 FT/0-610 M, In Canada 0-4500 FT/0-1370 M
vThe Steady State Efficiency numbers based on maximum vent configuration.
wTested to CSA P.4.1-02 “Testing Method for Measuring Annual Fireplace Efficiency.
Electrical Rating: 120 VAC, 60 HZ, Less Than 2 Amps