Lennox Hearth LMBV-42RMN Indoor Fireplace User Manual


 
7
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
LENNOX MERIT
®
SERIES B-VENT GAS FIREPLACES • 42" LMBV MODELS • CARE AND OPERATION INSTRUCTIONS
Figure 9
Figure 8
Maintenance
The appliance and venting system should be
thoroughly inspected before initial use and at
least annually by a qualified service technician.
Proper maintenance and use will require more
frequent, less extensive inspections and servic-
ing by the homeowner.
Generally, annual inspections should be per-
formed by a qualified service technician. More
frequent periodic inspections and cleanings
should be performed by the homeowner. Any
discrepancies discovered by the homeowner
should result in a call to a qualified service
technician to effect the repair or correction.
Refer to the maintenance schedule for main-
tenance tasks, procedures, periodicity and by
whom they should be performed.
IMPORTANT: TURN OFF GAS AND ANY
ELECTRICAL POWER BEFORE SERVICING
THE APPLIANCE.
Millivolt Appliance Checkout
The pilot flame should be steady, not lifting
or floating. Flame should be blue in color with
traces of orange at the outer edge.
The top ³⁄₈" (9 mm) at the pilot generator (ther-
mopile) should be engulfed in the pilot flame.
The ame should project 1" (25 mm) beyond
the hood at all three ports (Figure 9 ).
Electronic Appliance Checkout
Light the burner, refer to the Lightilng Instruc-
tions in this manual. Ensure the ignitor lights
the pilot. The pilot flame should engulf the
flame rod as shown in Figure 9.
With proper care and maintenance, your appli-
ance will provide many years of enjoyment. If
you should experience any problem, first refer
to the trouble shooting guide in this manual.
If problem persists, contact your Superior
distributor.
3/8" Min
(9 mm)
Hood
Pilot
Nozzels
Ignitor Rod
Proper Flame
Adjustment
Hot Surface
Igniter
Flame Rod
Ground
Electrode
3/8 To 1/2 Inch
(9 mm to 13 mm)
Pilot
Nozzle
MILLIVOLT
ELECTRONIC