Lennox Hearth LA41TCF Indoor Fireplace User Manual


 
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
7
Note: The framed depth, 28
¹⁄₈
" (714 mm) from
a framed wall, must always be measured from
a finished surface. If a wall covering such as
drywall is to be attached to the rear wall, then
the framed depth must be measured from the
drywall surface. It is important that this dimen-
sion be exact.
If the appliance is to be elevated above floor
level, a solid continuous platform must be
constructed.
The header may rest on the top metal spacers,
but must not be notched to fit around them.
Consult all local codes.
FRAMING SPECIFICATIONS
Figure 11
Header
Fireplace Framing
B
A
False
Header
H
Figure 12
Framing Dimensions for Ceiling
Flue Type A B
FTF10 Vertical 19" 19"
(483 mm) (483 mm)
FTF10 19" 29"
Offset 30° (483 mm) (737 mm)
Figure 13
A
Outside Chase
G
H
Back Wall of Chase/Enclosure
Including Finising Materials
if any
Rough
Framing Face
(Unfinished Shown)
FOAK
Combustion
Air Kit - Optional
Framing Dimensions for Roof
Pitch C D*
0/12 19" 19"
(483 mm) (483 mm)
6/12 19" 22"
(483 mm) (559 mm)
12/12 19" 27"
(483 mm) (686 mm)
* Perpendicular to roof ridge
Figure 15
Figure 16
Figure 14
A
B
Ceiling Framing
C
D
Roof Framing
Corner Installation
K
D
A
E
F
Back Wall of
Chase/Enclosure
Including Finising
Materials
if any
Rough
Framing Face
(Unfinished Shown)
FOAK Combustion
Air Kit - Optional
Framing Dimensions
Model LA41
A 50 ¹⁄₂" 1283 mm
B 53" 1346 mm
C 34 ⁵⁄₁₆" 873 mm
D 19 ¹⁄₈" 486 mm
E 90 ¹⁄₄" 2292 mm
F 45 ¹⁄₈" 1146 mm
G 28 ¹⁄₈" 714 mm
H 48 ³⁄₈" 1228 mm
J 26 ¹⁄₈" 664 mm
K 63 ¹¹⁄₁₆" 1622 mm
Note: All framing dimensions calculated for 1/2"
dry wall at the fireplace face. If sheathing the
chase or finishing with other thickness materials,
calculations will need to be made. False header
should be constructed of 2 x material only.
A
G
Inside Chase
Back Wall of Chase/Enclosure
Including Finising Materials if any
Rough
Framing Face
(Unfinished
Shown)
FOAK
Combustion
Air Kit